Evidence map›Paper›PMID 34548577›Full record

ArticleScientific reports2021

Sensitive and quantitative detection of cardiac troponin I with upconverting nanoparticle lateral flow test with minimized interference.

Sherif Bayoumy, Iida Martiskainen, Taina Heikkilä, Carita Rautanen, Pirjo Hedberg, Heidi Hyytiä, Saara Wittfooth, Kim Pettersson

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.9field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Sherif Bayoumy *Department of Biotechnology, University of Turku, Turku, Finland. shebay@utu.fi.
Iida Martiskainen *Department of Biotechnology, University of Turku, Turku, Finland.
Taina HeikkiläDepartment of Biotechnology, University of Turku, Turku, Finland.
Carita RautanenDepartment of Biotechnology, University of Turku, Turku, Finland.
Pirjo HedbergCancer Research and Translational Medicine Research Unit, Department of Clinical Chemistry, University of Oulu, Kajaanintie 50, 90220, Oulu, Finland.
Heidi HyytiäDepartment of Biotechnology, University of Turku, Turku, Finland.
Saara WittfoothDepartment of Biotechnology, University of Turku, Turku, Finland.
Kim PetterssonDepartment of Biotechnology, University of Turku, Turku, Finland.
University of Turku · FINordLab · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measurement of cardiac troponin I (cTnI) should be feasible for point-of-care testing (POCT) to diagnose acute myocardial infarction (AMI). Lateral flow immunoassays (LFIAs) have been long implemented in POCT and clinical settings. However, sensitivity, matrix effect and quantitation in lateral flow immunoassays (LFIAs) have been major limiting factors. The performance of LFIAs can be improved with upconverting nanoparticle (UCNP) reporters. Here we report a new methodological approach to quantify cTnI using UCNP-LFIA technology with minimized plasma interference. The performance of the developed UCNP-LFIA was evaluated using clinical plasma samples (n = 262). The developed UCNP-LFIA was compared to two reference assays, the Siemens Advia Centaur assay and an in-house well-based cTnI assay. By introducing an anti-IgM scrub line and dried EDTA in the LFIA strip, the detection of cTnI in plasma samples was fully recovered. The UCNP-LFIA was able to quantify cTnI concentrations in patient samples within the range of 30-10,000 ng/L. The LoB and LoD of the UCNP-LFIA were 8.4 ng/L and 30 ng/L. The method comparisons showed good correlation (Spearman's correlation 0.956 and 0.949, p < 0.0001). The developed UCNP-LFIA had LoD suitable for ruling in AMI in patients with elevated cTnI levels and was able to quantify cTnI concentrations in patient samples. The technology has potential to provide simple and rapid assay for POCT in ED setting.

Indexed as

CalibrationHumansImmunoassayLimit of DetectionMyocardial InfarctionNanoparticlesTroponin ITroponin I

Identifiers

PMID34548577
PMCPMC8455528
OpenAlexW3201230172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.