Evidence map›Paper›PMID 34546181›Full record

ArticleJournal of medical Internet research2021

A Fully Automated Analytic System for Measuring Endolymphatic Hydrops Ratios in Patients With Ménière Disease via Magnetic Resonance Imaging: Deep Learning Model Development Study.

Chae Jung Park, Young Sang Cho, Myung Jin Chung, Yi-Kyung Kim, Hyung-Jin Kim, Kyunga Kim, Jae-Wook Ko, Won-Ho Chung, Baek Hwan Cho

Abstract read
In one paragraph

Article in Journal of medical Internet research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. [Artificial intelligence applications in Ménière's disease].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2025
    Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Current State of Artificial Intelligence in Clinical Applications for Head and Neck MR Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2023
    Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chae Jung Park *Department of Digital Health, Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Republic of Korea.ORCID 0000-0002-1261-307X
Young Sang Cho *Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-4040-7206
Myung Jin ChungDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-6271-3343
Yi-Kyung KimDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-9395-4879
Hyung-Jin KimDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0003-3576-3625
Kyunga KimDepartment of Digital Health, Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Republic of Korea.ORCID 0000-0002-0865-2236
Jae-Wook KoDepartment of Clinical Pharmacology and Therapeutics, Samsung Medical Center, Seoul, Republic of Korea.ORCID 0000-0003-0962-2554
Won-Ho Chung *Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0001-7157-9935
Baek Hwan ChoDepartment of Medical Device Management and Research, Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Republic of Korea.ORCID 0000-0001-7722-5660

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, the analysis of endolymphatic hydropses (EHs) via inner ear magnetic resonance imaging (MRI) for patients with Ménière disease has been attempted in various studies. In addition, artificial intelligence has rapidly been incorporated into the medical field. In our previous studies, an automated algorithm for EH analysis was developed by using a convolutional neural network. However, several limitations existed, and further studies were conducted to compensate for these limitations.

objectiveThe aim of this study is to develop a fully automated analytic system for measuring EH ratios that enhances EH analysis accuracy and clinical usability when studying Ménière disease via MRI.

methodsWe proposed the 3into3Inception and 3intoUNet networks. Their network architectures were based on those of the Inception-v3 and U-Net networks, respectively. The developed networks were trained for inner ear segmentation by using the magnetic resonance images of 124 people and were embedded in a new, automated EH analysis system-inner-ear hydrops estimation via artificial intelligence (INHEARIT)-version 2 (INHEARIT-v2). After fivefold cross-validation, an additional test was performed by using 60 new, unseen magnetic resonance images to evaluate the performance of our system. The INHEARIT-v2 system has a new function that automatically selects representative images from a full MRI stack.

resultsThe average segmentation performance of the fivefold cross-validation was measured via the intersection of union method, resulting in performance values of 0.743 (SD 0.030) for the 3into3Inception network and 0.811 (SD 0.032) for the 3intoUNet network. The representative magnetic resonance slices (ie, from a data set of unseen magnetic resonance images) that were automatically selected by the INHEARIT-v2 system only differed from a maximum of 2 expert-selected slices. After comparing the ratios calculated by experienced physicians and those calculated by the INHEARIT-v2 system, we found that the average intraclass correlation coefficient for all cases was 0.941; the average intraclass correlation coefficient of the vestibules was 0.968, and that of the cochleae was 0.914. The time required for the fully automated system to accurately analyze EH ratios based on a patient's MRI stack was approximately 3.5 seconds.

conclusionsIn this study, a fully automated full-stack magnetic resonance analysis system for measuring EH ratios was developed (named INHEARIT-v2), and the results showed that there was a high correlation between the expert-calculated EH ratio values and those calculated by the INHEARIT-v2 system. The system is an upgraded version of the INHEARIT system; it has higher segmentation performance and automatically selects representative images from an MRI stack. The new model can help clinicians by providing objective analysis results and reducing the workload for interpreting magnetic resonance images.

Indexed as

Deep LearningEndolymphatic HydropsMeniere DiseaseArtificial IntelligenceHumansMagnetic Resonance Spectroscopyartificial intelligenceautomationclinical decision support systemclinical usabilityclinician supportconvolutional neural networkdeep learningendolymphatic hydropsend-to-end systemimage selectioninner earmachine learningmagnetic resonance imagingmedical image segmentationMénière diseasemulti-class segmentation

Identifiers

PMID34546181
PMCPMC8493456

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.