Evidence map›Paper›PMID 34546044›Full record

ArticleAnalytical chemistry2021

Cubosome Based Ion-Selective Optodes-Toward Tunable Biocompatible Sensors.

Emilia Stelmach, Ewa Nazaruk, Krzysztof Maksymiuk, Agata Michalska

Abstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Emilia StelmachFaculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.
Ewa NazarukFaculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.
Krzysztof MaksymiukFaculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.ORCID 0000-0002-3931-3798
Agata MichalskaFaculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.ORCID 0000-0002-8509-1428

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report here on a new generation of optical ion-selective sensors benefiting from cubosomes or hexosomes-nanostructural lipid liquid phase. Cubosome as well as hexosome optodes offer biocompatibility, self-assembly preparation, high stability in solution, and unique, tunable analytical performance. The temperature trigger reversibly changes the lipid nanoparticle internal structure-changing analyte access to the bulk of the probe and ultimately affecting the response pattern. Thus, cubosome or hexosome optodes are highly promising alternatives to conventional polymeric based optical nanoprobes.

Identifiers

PMID34546044
PMCPMC8495674

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.