Evidence map›Paper›PMID 34544852›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2021

An organic transistor matrix for multipoint intracellular action potential recording.

Yasutoshi Jimbo, Daisuke Sasaki, Takashi Ohya, Sunghoon Lee, Wonryung Lee, Faezeh Arab Hassani, Tomoyuki Yokota, Katsuhisa Matsuura, Shinjiro Umezu, Tatsuya Shimizu and 1 more

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yasutoshi JimboDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan.ORCID 0000-0003-0786-4920
Daisuke SasakiInstitute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, Tokyo 162-8666, Japan.
Takashi OhyaGraduate School of Creative Science and Engineering, Waseda University, Tokyo 169-8555, Japan.
Sunghoon LeeDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan.ORCID 0000-0002-3592-388X
Wonryung LeeDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan.
Faezeh Arab HassaniDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan.ORCID 0000-0003-4425-6289
Tomoyuki YokotaDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan.ORCID 0000-0003-1546-8864
Katsuhisa MatsuuraInstitute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, Tokyo 162-8666, Japan.
Shinjiro UmezuGraduate School of Creative Science and Engineering, Waseda University, Tokyo 169-8555, Japan.
Tatsuya ShimizuInstitute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, Tokyo 162-8666, Japan.ORCID 0000-0001-7601-4239
Takao SomeyaDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan; someya@ee.t.u-tokyo.ac.jp.ORCID 0000-0003-3051-1138

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrode arrays are widely used for multipoint recording of electrophysiological activities, and organic electronics have been utilized to achieve both high performance and biocompatibility. However, extracellular electrode arrays record the field potential instead of the membrane potential itself, resulting in the loss of information and signal amplitude. Although much effort has been dedicated to developing intracellular access methods, their three-dimensional structures and advanced protocols prohibited implementation with organic electronics. Here, we show an organic electrochemical transistor (OECT) matrix for the intracellular action potential recording. The driving voltage of sensor matrix simultaneously causes electroporation so that intracellular action potentials are recorded with simple equipment. The amplitude of the recorded peaks was larger than that of an extracellular field potential recording, and it was further enhanced by tuning the driving voltage and geometry of OECTs. The capability of miniaturization and multiplexed recording was demonstrated through a 4 × 4 action potential mapping using a matrix of 5- × 5-μm

Indexed as

Action PotentialsBiosensing TechniquesCells, CulturedElectroporationHumansInduced Pluripotent Stem CellsMyocytes, CardiacTransistors, Electronicaction potential mappingbiomonitoring interfaceintracellular recordingorganic electrochemical transistororganic electronics

Identifiers

PMID34544852
PMCPMC8488610

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.