ArticleBiomechanics and modeling in mechanobiology2021

Influence of shape-memory stent grafts on local aortic compliance.

J Concannon, K M Moerman, N Hynes, S Sultan, J P McGarry

Open access · hybridAbstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

J ConcannonBiomedical Engineering, College of Engineering and Informatics, National University of Ireland, Galway, Ireland.
K M MoermanBiomedical Engineering, College of Engineering and Informatics, National University of Ireland, Galway, Ireland.
N HynesWestern Vascular Institute, National University of Ireland Galway, Galway, Ireland.
S SultanWestern Vascular Institute, National University of Ireland Galway, Galway, Ireland.
J P McGarryBiomedical Engineering, College of Engineering and Informatics, National University of Ireland, Galway, Ireland. patrick.mcgarry@nuigalway.ie.
Ollscoil na Gaillimhe – University of Galway · IE

Funding

Irish Research Council EPSPG_2016_194
6 · The paper itself

Abstract

The effect of repair techniques on the biomechanics of the aorta is poorly understood, resulting in significant levels of postoperative complications for patients worldwide. This study presents a computational analysis of the influence of Nitinol-based devices on the biomechanical performance of a healthy patient-specific human aorta. Simulations reveal that Nitinol stent-grafts stretch the artery wall so that collagen is stretched to a straightened high-stiffness configuration. The high-compliance regime (HCR) associated with low diastolic lumen pressure is eliminated, and the artery operates in a low-compliance regime (LCR) throughout the entire cardiac cycle. The slope of the lumen pressure-area curve for the LCR post-implantation is almost identical to that of the native vessel during systole. This negligible change from the native LCR slope occurs because the stent-graft increases its diameter from the crimped configuration during deployment so that it reaches a low-stiffness unloading plateau. The effective radial stiffness of the implant along this unloading plateau is negligible compared to the stiffness of the artery wall. Provided the Nitinol device unloads sufficiently during deployment to the unloading plateau, the degree of oversizing has a negligible effect on the pressure-area response of the vessel, as each device exerts approximately the same radial force, the slope of which is negligible compared to the LCR slope of the native artery. We show that 10% oversizing based on the observed diastolic diameter in the mid descending thoracic aorta results in a complete loss of contact between the device and the wall during systole, which could lead to an endoleak and stent migration. 20% oversizing reaches the Dacron enforced area limit (DEAL) during the pulse pressure and results in an effective zero-compliance in the later portion of systole.

Indexed as

Blood Vessel ProsthesisStentsAlloysAortaArteriesFinite Element AnalysisHumansMagnetic Resonance ImagingMembranes, ArtificialModels, CardiovascularNonlinear DynamicsPressureSmart MaterialsAlloysMembranes, ArtificialnitinolSmart MaterialsAortic complianceCollagenFinite elementStent-graft

Identifiers

PMID34541627
PMCPMC8595172
OpenAlexW3198979174

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.