ArticleMedical physics2021
An interactive eye-tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye-tracking accuracy validation.
Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 11 citations in OpenAlex.
- Reading, Fast and Slow: Characterizing Radiologists' Visual Search Through Abdominal CT for Detecting Hepatic Metastases.Academic radiology · 2026Article
- Peripheral liver metastases are more frequently missed than central metastases in contrast-enhanced CT: insights from a 25-reader performance study.Abdominal radiology (New York) · 2025Article
- Development and validation of an AMR-based predictive model for post-PCI contrast-induced nephropathy in patients with acute ST-segment elevation myocardial infarction.Frontiers in cardiovascular medicine · 2025Review
- Development and validation of an AMR-based predictive model for post-PCI upper gastrointestinal bleeding in NSTEMI patients.Frontiers in endocrinology · 2025Article
- Targeted Training Reduces Search Errors but Not Classification Errors for Hepatic Metastasis Detection at Contrast-Enhanced CT.Academic radiology · 2024Article
- Understanding Reader Variability: A 25-Radiologist Study on Liver Metastasis Detection at CT.Radiology · 2023Observational
- Interactive method research of dual mode information coordination integration for astronaut gesture and eye movement signals based on hybrid model.Science China. Technological sciences · 2023Article
- Implementation and initial experience with an interactive eye-tracking system for measuring radiologists' visual search in diagnostic tasks using volumetric CT images.Proceedings of SPIE--the International Society for Optical EngineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 1 country.
Funding
Abstract
purposeEye-tracking approaches have been used to understand the visual search process in radiology. However, previous eye-tracking work in computer tomography (CT) has been limited largely to single cross-sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three-dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye-tracking hardware with in-house-developed reader workstation software to allow monitoring of the visual search process and reader-image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye-tracking data using this platform for different eye-tracking data acquisition modes.
methodsAn eye-tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real-time eye movement and workstation events at 1000 Hz sampling frequency. The eye-tracker was operated either in head-stabilized mode or in free-movement mode. In head-stabilized mode, the reader positioned their head on a manufacturer-provided chinrest. In free-movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye-tracking spatial accuracy under three constraint conditions: head-stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross-hair target prior to the integration of the eye-tracker with the image viewing workstation. In Study 2, after integration of the eye-tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.
resultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye-tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.
conclusionsAn integrated eye-tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head-free movement condition with audio biofeedback performed similarly to head-stabilized mode.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.