Evidence map›Paper›PMID 34532620›Full record

ArticleSpartan medical research journal2021

Comparing Postoperative Leg Length Discrepancy and Femoral Offset Using Two Different Surgical Approaches for Hemiarthroplasty of the Hip.

James T Layson, Matthew S Coon, Rajan Sharma, Benjamin Diedring, Alan Afsari, Benjamin Best

Open access · hybridAbstract read
In one paragraph

Article in Spartan medical research journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

James T LaysonAscension Macomb Oakland Hospital.
Matthew S CoonAscension Macomb Oakland Hospital.
Rajan SharmaAscension Macomb Oakland Hospital.
Benjamin DiedringAscension Macomb Oakland Hospital.
Alan AfsariAscension St. John Hospital.
Benjamin BestAscension St. John Hospital.
St. John Macomb Oakland Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe direct anterior approach (DAA) and anterolateral approach (ALA) may be used for hip hemiarthroplasty (HHA) as a treatment for femoral neck fractures. The DAA often utilizes intraoperative fluoroscopy to determine leg length and offset, while the ALA traditionally utilizes an intraoperative clinical exam to determine offset and leg length. This study will evaluate two techniques: the "grid fluoroscopy [GF] technique" and the "intraoperative exam [IE] technique," each performed by one of two separate surgeons, and compare each technique's accuracy to restore leg length and femoral offset in a patient population that underwent HHA.

methodsTwo investigators retrospectively reviewed charts of 208 randomly selected patients who had an HHA from either a DAA or ALA performed by two different surgeons for the treatment of femoral neck fractures. Postoperative AP pelvis radiographs were measured to determine offset and leg length compared with the non-operative extremity. Non-normal continuous variables were provided by median and interquartile range. Data were analyzed with the Mann-Whitney U test and Student's t-test.

resultsAfter inclusion and exclusion criteria, data were reviewed on 173 hemiarthroplasties. The mean age was 80.3 years (± 11.2 years). Of the surgical patients, 65.9% were female, and 70.9% identified their ethnicity as white. The DAA was used in 93 patients and ALA in 80 patients. Analysis comparing the two techniques demonstrated no statistically significant differences in median leg length between GF technique (1.02 IQR -0.1, 2.0 mm) and IE technique (1.25 IQR -2.4, 1.3 mm,) (p=0.67). There was also no statistically significant difference in offset between GF technique (1.3 IQR 0.2, 2.1 mm) and IE technique (0.6 IQR -2.7 mm, 3.2 mm) (p=0.13). However, a difference was found in mean length of surgery that was statistically significant. We found that the mean length of surgery for the IE technique was 74.8 ± 24.7 minutes versus the GF technique, which was 95.1 ± 23.0 minutes, (p<0.0001). DISCUSSION: There was no significant difference between leg length and offset with the use of intraoperative fluoroscopy with DAA compared to no intraoperative imaging with ALA. Our study suggests that DAA and ALA are equally effective approaches for re-establishing symmetric leg length and offset in HHA for femoral neck fractures. In this study, the ALA had a shorter surgical time compared to DAA, potentially due to the utilization of intraoperative fluoroscopy for this particular technique during the DAA.

Indexed as

anterolateral approachdirect anterior approachhemiarthroplastyleg length discrepancyorthopaedic surgery

Identifiers

PMID34532620
PMCPMC8405281
OpenAlexW3197505485

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.