Evidence map›Paper›PMID 34532263›Full record

ArticleTranslational andrology and urology2021

Holographic reconstruction technology used for intraoperative real-time navigation in robot-assisted partial nephrectomy in patients with renal tumors: a single center study.

Shaohua Zeng, Yu Zhou, Min Wang, Hui Bao, Yanqun Na, Tiejun Pan

Open access · diamondAbstract read
In one paragraph

Article in Translational andrology and urology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Visual extended reality tools in image-guided surgery in urology: a systematic review.European journal of nuclear medicine and molecular imaging · 2024
    Pooled it
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Shaohua ZengThe First School of Clinical Medicine, Southern Medical University, Guangzhou, China.
Yu ZhouDepartment of Urology, General Hospital of the Central Theater Command, Wuhan, China.
Min WangDepartment of Urology, General Hospital of the Central Theater Command, Wuhan, China.
Hui BaoDepartment of Urology, General Hospital of the Central Theater Command, Wuhan, China.
Yanqun NaDepartment of Urology, Peking University Shougang Hospital, Peking University Health Science Center, Beijing, China.
Tiejun PanDepartment of Urology, General Hospital of the Central Theater Command, Wuhan, China.
Central Hospital of Wuhan · CNPeking University Shougang Hospital · CNSouthern Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo explore the efficacy and advantages of real-time navigation using holographic reconstruction (HR) technology combined with da VinciTM robotic system for partial nephrectomy (PN) in patients with renal tumor.

methodsThe clinical data of 41 patients with totally intrarenal tumors receiving robot-assisted partial nephrectomy (RAPN) from April 2018 to October 2020 in our department were collected and retrospectively analyzed. All operations were performed by the same surgeon. HR technology and three-dimensional (3D) reconstruction techniques were applied for real-time navigation to resect tumors using the da VinciTM robotic system. The relevant clinical parameters and surgical outcomes of the patients were recorded and analyzed.

resultsHR technology allowed accurate evaluation of tumors, renal hilus vessels, and surrounding organs during the operation. With real-time navigation HR, all cases were performed by RAPN. The mean operative time was 115.3±20.3 (range, 70-153) minutes, and the warm ischemia time (WIT) was 18.7±3.9 (range, 13-28) minutes. The estimated blood loss (EBL) was 98.8±18.7 (range, 60-141) mL. Negative surgical margins were reported in all cases. Patients with absence of grade ≤1 Clavien-Dindo complications. Compared with the clinical outcomes of standard RAPN, as reported in the literature, HR-assisted technology reduced the mean operative time, the WIT, and the EBL in patients undergoing RAPN. Therefore, combining HR with robotic abdominal surgery can enhance the efficiency of locating blood vessels and allow for more accurate resection of tumors.

conclusionsAs a novel and promising computer digital technology, HR can significantly improve the success of RAPN operations. This retrospective study demonstrated that HR-assisted operations resulted in shorter operation times and less perioperative complications and were thus safer and more effective in patients with renal tumors compared with RAPN not used HR.

Indexed as

Holographic reconstructions (HRs)real-time navigationrenal cell carcinomarobot-assisted partial nephrectomy (RAPN)

Identifiers

PMID34532263
PMCPMC8421827
OpenAlexW3193980311

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked