Evidence map›Paper›PMID 34532175›Full record

ArticleCureus2021

Development of a Three-Dimensionally Printed Ultrasound-Guided Peripheral Intravenous Catheter Phantom.

Ting Xu Tan, Ying Ying Wu, Ian Riley, Youyou Duanmu, Samuel Rylowicz, Kenji Shimada

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Ting Xu TanDepartment of Emergency Medicine, Stanford University School of Medicine, Stanford, USA.
Ying Ying WuDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, USA.
Ian RileyDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, USA.
Youyou DuanmuDepartment of Emergency Medicine, Stanford University School of Medicine, Stanford, USA.
Samuel RylowiczDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, USA.
Kenji ShimadaDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, USA.
Carnegie Mellon University · USStanford University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Ultrasound-guided peripheral intravenous catheter (US-PIVC) placement is an effective technique to establish PIV access when the traditional approach fails. Many training programs utilize commercial or homemade phantoms for procedural training. However, commercial products tend to be expensive and lack realism, while homemade blocks tend to be single-use and degrade easily. Thanks to the increasing availability of three-dimensional (3D) printers in academic settings, we sought to design and develop a reusable 3D-printed US-PIVC phantom and to evaluate its utility in terms of time needed to achieve IV placement and perceived realism compared to a commercial model among a group of emergency medicine (EM) physicians. Methods The upper extremity vascular phantom was constructed using 3D printing and casting techniques. A convenience sampling of EM physicians was timed by placing a US-PIVC in the 3D-printed and commercial models. Participants were also surveyed to assess their impression of the realism of the models. The primary outcome was the time required for US-PIVC placement in the 3D-printed model compared to the commercial model. Secondary outcomes were the assessment of differences in perceived realism and total cost between the two models. Results Twenty-one EM physicians completed the study. There were no significant differences in the mean time (seconds) for US-PIVC placement in the 3D-printed model (31, SD: 21) compared to the commercial model (30, SD: 18), p=0.77. Mean realism score trended higher for the 3D-printed model (3.6, SD: 0.9) compared to the commercial model (3.1, SD: 1.0), p=0.10. The total cost for the 3D-printed model was $120, with the interchangeable replacement part costing $21, which was much cheaper compared to the commercial phantom, which cost $549. Conclusion We developed a 3D-printed reusable US-PIVC phantom, and it proved to be more economical without sacrificing the realism and time required for US-PIVC placement when compared to a commercial phantom.

Indexed as

emergency medicine procedureslow-cost task trainersperipheral vascularsimulation in medical educationsimulation trainerteaching proceduresthree-dimensional (3d) printingultrasound-guided

Identifiers

PMID34532175
PMCPMC8435066
OpenAlexW3195112419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.