Evidence map›Paper›PMID 34531486›Full record

ArticleScientific reports2021

Tunable X-ray dark-field imaging for sub-resolution feature size quantification in porous media.

Benjamin K Blykers, Caori Organista, Matthieu N Boone, Matias Kagias, Federica Marone, Marco Stampanoni, Tom Bultreys, Veerle Cnudde, Jan Aelterman

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Laboratory-based x-ray dark-field microscopy.Physical review applied · 2023
    Article
  3. Characterization of Pharmaceutical Tablets by X-ray Tomography.Pharmaceuticals (Basel, Switzerland) · 2023
    Review
  4. The Anatomy of Amorphous, Heterogeneous Catalyst Pellets.Materials (Basel, Switzerland) · 2023
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Benjamin K BlykersPore-Scale Processes in Geomaterials Research Group (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000, Ghent, Belgium. benjamin.blykers@ugent.be.
Caori OrganistaSwiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland.
Matthieu N BooneGhent University Centre for X-Ray Tomography (UGCT), Proeftuinstraat 86/N12, 9000, Ghent, Belgium.
Matias KagiasSwiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland.
Federica MaroneSwiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland.
Marco StampanoniSwiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland.
Tom BultreysPore-Scale Processes in Geomaterials Research Group (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000, Ghent, Belgium.
Veerle CnuddePore-Scale Processes in Geomaterials Research Group (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000, Ghent, Belgium.
Jan AeltermanGhent University Centre for X-Ray Tomography (UGCT), Proeftuinstraat 86/N12, 9000, Ghent, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray computed micro-tomography typically involves a trade-off between sample size and resolution, complicating the study at a micrometer scale of representative volumes of materials with broad feature size distributions (e.g. natural stones). X-ray dark-field tomography exploits scattering to probe sub-resolution features, promising to overcome this trade-off. In this work, we present a quantification method for sub-resolution feature sizes using dark-field tomograms obtained by tuning the autocorrelation length of a Talbot grating interferometer. Alumina particles with different nominal pore sizes (50 nm and 150 nm) were mixed and imaged at the TOMCAT beamline of the SLS synchrotron (PSI) at eighteen correlation lengths, covering the pore size range. The different particles cannot be distinguished by traditional absorption µCT due to their very similar density and the pores being unresolved at typical image resolutions. Nevertheless, by exploiting the scattering behavior of the samples, the proposed analysis method allowed to quantify the nominal pore sizes of individual particles. The robustness of this quantification was proven by reproducing the experiment with solid samples of alumina, and alumina particles that were kept separated. Our findings demonstrate the possibility to calibrate dark-field image analysis to quantify sub-resolution feature sizes, allowing multi-scale analyses of heterogeneous materials without subsampling.

Identifiers

PMID34531486
PMCPMC8446041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.