ArticleOptics letters2021
Multi-exposure interferometric diffusing wave spectroscopy.
Article in Optics letters, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- Compact FPGA-based software correlator for real-time blood flow measurement with diffuse correlation spectroscopy.Biomedical optics express · 2026Article
- Depth-sensitive cerebral blood flow and low-frequency oscillations for consciousness assessment using time-domain diffuse correlation spectroscopy.Neurophotonics · 2026Article
- Comparative validation of speckle contrast optical spectroscopy against diffuse correlation spectroscopy for monitoring human cerebral blood flow.Neurophotonics · 2026Article
- Highly parallel, 1060 nm interferometric diffusing wave spectroscopy with a time-of-flight filter.Biomedical optics express · 2026Article
- Depth-sensitive assessment of cerebral blood flow and low-frequency oscillations after traumatic brain injury in mice using time-domain diffuse correlation spectroscopy.Neurophotonics · 2026Article
- Beneath the surface: revealing deep-tissue blood flow in human subjects with massively parallelized diffuse correlation spectroscopy.Neurophotonics · 2025Article
- Tunable dynamical tissue phantom for laser speckle imaging.Biomedical optics express · 2024Article
- Article
- Diffuse Correlation Spectroscopy: A Review of Recent Advances in Parallelisation and Depth Discrimination Techniques.Sensors (Basel, Switzerland) · 2023Review
- Article
- Portable, high speed blood flow measurements enabled by long wavelength, interferometric diffuse correlation spectroscopy (LW-iDCS).Scientific reports · 2023Article
- Massively parallel, real-time multispeckle diffuse correlation spectroscopy using a 500 × 500 SPAD camera.Biomedical optics express · 2023Article
- Interferometric diffusing wave spectroscopy imaging with an electronically variable time-of-flight filter.Optica · 2023Article
- Diffuse correlation spectroscopy: current status and future outlook.Neurophotonics · 2023Article
- Interferometric diffuse optics: recent advances and future outlook.Neurophotonics · 2023Article
- Laser speckle simulation tool based on stochastic differential equations for bio imaging applications.Biomedical optics express · 2022Article
- High-density diffuse correlation tomography with enhanced depth localization and minimal surface artefacts.Biomedical optics express · 2022Article
- Optical imaging and spectroscopy for the study of the human brain: status report.Neurophotonics · 2022Article
- Performance optimisation of a holographic Fourier domain diffuse correlation spectroscopy instrument.Biomedical optics express · 2022Article
- Comprehensive Optimization of Interferometric Diffusing Wave Spectroscopy (iDWS).IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
We present multi-exposure interferometric diffusing wave spectroscopy (MiDWS), which measures brain blood flow index (BFI) continuously and non-invasively. MiDWS employs interferometry to detect low light levels, probing the optical field autocorrelation indirectly by varying the sensor exposure time. Here MiDWS is compared with conventional interferometric diffusing wave spectroscopy and speckle contrast optical spectroscopy in phantoms. Notably, the MiDWS approach enables the use of low frame rate, two-dimensional complementary metal-oxide semiconductor cameras in a short exposure time regime, where detector noise greatly exceeds the sample photon count. Finally, we show that MiDWS can monitor the BFI simultaneously at two source-collector separations (1 and 3 cm) on the adult human head on a single camera, enabling the use of superficial signal regression techniques to improve brain specificity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.