Evidence map›Paper›PMID 34522394›Full record

ArticleHealth SA = SA Gesondheid2021

Local diagnostic reference levels for routine chest X-ray examinations at a public sector hospital in central South Africa.

Maurice Junda, Henra Muller, Hesta Friedrich-Nel

Open access · goldAbstract read
In one paragraph

Article in Health SA = SA Gesondheid, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Maurice JundaDepartment of Clinical Sciences, Faculty of Health and Environmental Sciences, Central University of Technology, Bloemfontein, South Africa.ORCID https://orcid.org/0000-0002-0632-5493
Henra MullerDepartment of Clinical Sciences, Faculty of Health and Environmental Sciences, Central University of Technology, Bloemfontein, South Africa.ORCID https://orcid.org/0000-0002-1362-4299
Hesta Friedrich-NelDepartment of Clinical Sciences, Faculty of Health and Environmental Sciences, Central University of Technology, Bloemfontein, South Africa.ORCID https://orcid.org/0000-0002-1347-8914
Central University of Technology · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDose optimisation is a radiation protection guideline recommended by the International Commission on Radiological Protection (ICRP) for adherence to the 'as low as reasonably achievable' (ALARA) principle. Diagnostic reference levels (DRLs) are used to optimise patients' radiation protection for diagnostic and interventional procedures and are particularly useful for frequently performed examinations such as chest X-rays.

aimTo establish the local diagnostic reference levels (LDRLs) for routine chest X-rays.

settingPublic sector hospital, Northern Cape province, South Africa.

methodsSixty patients referred for chest X-rays fulfilling the inclusion criteria participated in this study. Patients were ≥ 18 years of age and weighed between 60 kg and 80 kg. Consent for participation was obtained. The entrance skin air kerma (ESAK) was measured by using the indirect method recommended by the International Atomic Energy Agency (IAEA). Statistical software (SAS version 9.2) was used to determine the LDRLs for chest X-rays in three different rooms. In two rooms, computed radiography (CR) was used and the other one was a digital radiography (DR) unit. The LDRL values at the research site were compared with various published international values.

resultsLDRLs for chest X-rays were established. The CR LDRL value for the posteroanterior (PA) chest projection was higher than the DR (flat panel detector [FPD]) LDRL value. The LDRLs of the PA chest projections were 0.3 mGy for CR and 0.2 mGy for DR. The lateral (LAT) chest projection LDRL value was 0.8 mGy for both CR and DR (FPD) projections. The resultant LDRL between rooms at the research site was 0.3 mGy for PA 0.3 mGy and 0.8 mGy for LAT chest projections.

conclusionThe LDRLs for chest X-rays established at this research site were lower than internationally reported DRLs. We recommend that LDRLs for routine chest X-rays should be repeated every 3 years, according to the ICRP. CONTRIBUTION: Currently, no established or published DRL values prescribed by the Directorate of Radiation Control (DRC) are available in South Africa. The LDRLs established for routine chest X-ray examinations at this research site can serve as a guideline for the establishment of DRL values for other anatomical regions at the research site and other radiology departments in the country.

Indexed as

ALARAchest X-raydiagnostic reference levelsdigital radiographyDRLsentrance surface air kerma

Identifiers

PMID34522394
PMCPMC8424719
OpenAlexW3193704805

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.