Evidence map›Paper›PMID 34521937›Full record

ArticleScientific reports2021

A negative piezo-conductive effect from doped semiconducting polymer thin films.

Chao Yi, Lening Shen, Jie Zheng, Xiong Gong

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chao Yi *School of Polymer Science and Polymer Engineering, The University of Akron, Akron, OH, 44325, USA.
Lening Shen *School of Polymer Science and Polymer Engineering, The University of Akron, Akron, OH, 44325, USA.
Jie ZhengDepartment of Chemical, Biomolecular and Corrosion Engineering, College of Engineering and Polymer Science, The University of Akron, Akron, OH, 44325, USA.
Xiong GongSchool of Polymer Science and Polymer Engineering, The University of Akron, Akron, OH, 44325, USA. xgong@uakron.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the past years, piezo-conductive sensors have drawn great attention in both academic and industrial sectors. The piezo-conductive sensors made by inorganic semiconductors exhibited poor mechanical flexibility, restricting their further practical applications. In this study, we report the piezo-conductive sensors by a semiconducting polymer, poly(3,4-ethylenedioxythiophene) doped with tosylate ions (PEDOT:Tos) thin films. Systemically studies indicate that the piezo-conductive response of the PEDOT:Tos thin films is originated from the deformation of the PEDOT crystal cells and the stretched π-π distances induced by Tos. Moreover, the negative piezo-conductive effect, for the first time, is observed from PEDOT:Tos thin film under the pressure. A working mechanism is further proposed to interpret the transient from a positive to a negative piezo-conductive response within the PEDOT:Tos thin films. Our studies offer a facile route to approach effective piezo-conductive sensors based on conjugated polymers.

Identifiers

PMID34521937
PMCPMC8440650

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.