Evidence map›Paper›PMID 34519954›Full record

ArticleJournal of digital imaging2021

3D Isotropic Super-resolution Prostate MRI Using Generative Adversarial Networks and Unpaired Multiplane Slices.

Yucheng Liu, Yulin Liu, Rami Vanguri, Daniel Litwiller, Michael Liu, Hao-Yun Hsu, Richard Ha, Hiram Shaish, Sachin Jambawalikar

Open access · greenAbstract read
In one paragraph

Article in Journal of digital imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Yucheng LiuDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA. yl3830@cumc.columbia.edu.ORCID 0000-0003-0235-9247
Yulin LiuDepartment of Information and Computer Engineering, Chung Yuan Christian University, Chung Li District, 200 Chung Pei Road, Taoyuan City, Taiwan.
Rami VanguriComputational Oncology Service, Department of Epidemiology & Biostatistics, Memorial Sloan, Kettering Cancer Center 485 Lexington Ave, New York, NY, 10017, USA.
Daniel LitwillerGlobal MR Applications and Workflow, GE Healthcare, New York, NY, USA.
Michael LiuDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA.
Hao-Yun HsuDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA.
Richard HaDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA.
Hiram ShaishDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA.
Sachin JambawalikarDepartment of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA.
Columbia University Irving Medical Center · USChung Yuan Christian University · TWGE Global Research (United States) · USMemorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Hongbiao Carl Lekaye · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

We developed a deep learning-based super-resolution model for prostate MRI. 2D T2-weighted turbo spin echo (T2w-TSE) images are the core anatomical sequences in a multiparametric MRI (mpMRI) protocol. These images have coarse through-plane resolution, are non-isotropic, and have long acquisition times (approximately 10-15 min). The model we developed aims to preserve high-frequency details that are normally lost after 3D reconstruction. We propose a novel framework for generating isotropic volumes using generative adversarial networks (GAN) from anisotropic 2D T2w-TSE and single-shot fast spin echo (ssFSE) images. The CycleGAN model used in this study allows the unpaired dataset mapping to reconstruct super-resolution (SR) volumes. Fivefold cross-validation was performed. The improvements from patch-to-volume reconstruction (PVR) to SR are 80.17%, 63.77%, and 186% for perceptual index (PI), RMSE, and SSIM, respectively; the improvements from slice-to-volume reconstruction (SVR) to SR are 72.41%, 17.44%, and 7.5% for PI, RMSE, and SSIM, respectively. Five ssFSE cases were used to test for generalizability; the perceptual quality of SR images surpasses the in-plane ssFSE images by 37.5%, with 3.26% improvement in SSIM and a higher RMSE by 7.92%. SR images were quantitatively assessed with radiologist Likert scores. Our isotropic SR volumes are able to reproduce high-frequency detail, maintaining comparable image quality to in-plane TSE images in all planes without sacrificing perceptual accuracy. The SR reconstruction networks were also successfully applied to the ssFSE images, demonstrating that high-quality isotropic volume achieved from ultra-fast acquisition is feasible.

Indexed as

Imaging, Three-DimensionalProstateHumansMagnetic Resonance ImagingMaleGenerative adversarial networkImage qualityProstate MRISuper-resolution

Identifiers

PMID34519954
PMCPMC8555005
OpenAlexW3200840358

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.