Evidence map›Paper›PMID 34519921›Full record

ArticleApplied biochemistry and biotechnology2022

Development of a Novel Bioluminescence Pyrophosphate Assay for the High-Sensitivity Detection of Hepatitis B Virus.

Guolei Tan, Zhongjie Fei, Rongbin Wei, Xuping Wu, Pengfeng Xiao

Abstract read
PubMed Publisher
In one paragraph

Article in Applied biochemistry and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Guolei TanThe Second Hospital of Nanjing, Nanjing University of Chinese Medicine, Zhong Fu Lu 1#, Gulou District, Nanjing, 210003, China.
Zhongjie FeiState Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2#, Xuanwu District, Nanjing, 210096, China.
Rongbin WeiState Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2#, Xuanwu District, Nanjing, 210096, China.
Xuping WuThe Second Hospital of Nanjing, Nanjing University of Chinese Medicine, Zhong Fu Lu 1#, Gulou District, Nanjing, 210003, China. xuping.wu@njucm.edu.cn.ORCID http://orcid.org/0000-0002-1713-3753
Pengfeng XiaoState Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2#, Xuanwu District, Nanjing, 210096, China. xiaopf@seu.edu.cn.
Nanjing University of Chinese Medicine · CNState Key Laboratory of Digital Medical EngineeringBioElectronics (United States) · US

Funding

Jiangsu Provincial Commission of Health (CN) LGY2020015National Natural Science Foundation of China 61571114National Natural Science Foundation of China 61971123
6 · The paper itself

Abstract

The transmission of bloodborne viruses through transfusion remains a major blood supply-related safety concern, with hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) being the most important pathogens in this context. Real-time bioluminescent pyrophosphate testing has been developed as a means of readily detecting bacterial cells within particular sample types without requiring the use of expensive or complex instrumentation. The sensitivity of this approach, however, is often limited such that it is not compatible with many potential applications. In this study, we sought to overcome the limitations of this pyrophosphate bioluminescent assay format by using 2-deoxyadenosine-5-(α-thio)-triphosphate (dATPαS) in place of dATP for PCR amplification, thereby dramatically reducing background signal levels. We leveraged this combination PCR and bioluminescent pyrophosphate assay approach to facilitate HBV detection. This assay yielded a limit of detection of 500 copies/mL, making it more sensitive than traditional bioluminescent assays, about 1000 times more sensitive than that of PCR product analysis by agarose gel electrophoresis, and roughly as sensitive as qPCR as a means of detecting viral DNA. We then used this assay to analyze 100 serum samples, with qPCR being used for result validation. The assay required 100 min to complete, and was able to detect as few as 500 copies/mL of viral DNA. Overall, our approach was rapid, sensitive, and simple, enabling users to readily detect HBV in a reliable and efficient manner.

Indexed as

DiphosphatesHepatitis B virusLuminescent MeasurementsDNA, ViralHepatitis BHumansLimit of DetectionDiphosphatesdiphosphoric acidDNA, ViralHBV applicationNew bioluminescent pyrophosphate assayPCRRapid and high-sensitivity detection

Identifiers

PMID34519921
OpenAlexW3200553438

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.