ArticleCalcified tissue international2022
Validation of a Semiautomatic Image Analysis Software for the Quantification of Musculoskeletal Tissues.
Article in Calcified tissue international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- AutoLMISeg: A Fully Automated Pipeline for 3D Lumbar Muscle Volumetry and Densitometry on CT - Technical Validation Against an Operator-Driven Workflow.Journal of imaging informatics in medicine · 2026Article
- Integration of sarcopenia screening into radiotherapy planning: Validation of a time-efficient SMI measurement method using MIM software in prostate cancer.Journal of applied clinical medical physics · 2026Article
- FocusedON-BC: A Robust Deep Learning Framework for Automated Body Composition Assessment.Nutrients · 2026Article
- Accuracy of pelvic bone segmentation for 3d printing: a study of segmentation accuracy based on anatomic landmarks to evaluate the influence of the observer.3D printing in medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
Abstract
Accurate quantification of bone, muscle, and their components is still an unmet need in the musculoskeletal field. Current methods to quantify tissue volumes in 3D images are expensive, labor-intensive, and time-consuming; thus, a reliable, valid, and quick application is highly needed. Tissue Compass is a standalone software for semiautomatic segmentation and automatic quantification of musculoskeletal organs. To validate the software, cross-sectional micro-CT scans images of rat femur (n = 19), and CT images of hip and abdomen (n = 100) from the Osteoporotic Fractures in Men (MrOS) Study were used to quantify bone, hematopoietic marrow (HBM), and marrow adipose tissue (MAT) using commercial manual software as a comparator. Also, abdominal CT scans (n = 100) were used to quantify psoas muscle volumes and intermuscular adipose tissue (IMAT) using the same software. We calculated Pearson's correlation coefficients, individual intra-class correlation coefficients (ICC), and Bland-Altman limits of agreement together with Bland-Altman plots to show the inter- and intra-observer agreement between Tissue Compass and commercially available software. In the animal study, the agreement between Tissue Compass and commercial software was r > 0.93 and ICC > 0.93 for rat femur measurements. Bland-Altman limits of agreement was - 720.89 (- 1.5e+04, 13,074.00) for MAT, 4421.11 (- 1.8e+04, 27,149.73) for HBM and - 6073.32 (- 2.9e+04, 16,388.37) for bone. The inter-observer agreement for QCT human study between two observers was r > 0.99 and ICC > 0.99. Bland-Altman limits of agreement was 0.01 (- 0.07, 0.10) for MAT in hip, 0.02 (- 0.08, 0.12) for HBM in hip, 0.05 (- 0.15, 0.25) for bone in hip, 0.02 (- 0.18, 0.22) for MAT in L1, 0.00 (- 0.16, 0.16) for HBM in L1, and 0.02 (- 0.23, 0.27) for bone in L1. The intra-observer agreement for QCT human study between the two applications was r > 0.997 and ICC > 0.99. Bland-Altman limits of agreement was 0.03 (- 0.13, 0.20) for MAT in hip, 0.05 (- 0.08, 0.18) for HBM in hip, 0.05 (- 0.24, 0.34) for bone in hip, - 0.02 (- 0.34, 0.31) for MAT in L1, - 0.14 (- 0.44, 0.17) for HBM in L1, - 0.29 (- 0.62, 0.05) for bone in L1, 0.03 (- 0.08, 0.15) for IMAT in psoas, and 0.02 (- 0.35, 0.38) for muscle in psoas. Compared to a conventional application, Tissue Compass demonstrated high accuracy and non-inferiority while also facilitating easier analyses. Tissue Compass could become the tool of choice to diagnose tissue loss/gain syndromes in the future by requiring a small number of CT sections to detect tissue volumes and fat infiltration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.