Evidence map›Paper›PMID 34518600›Full record

ArticleScientific reports2021

Fluorescent lamp tungsten filament thermionic emission gun as a novel humidity optical sensor.

Hossein Torabi-Monfared, Leila Sherafat, Mohammad Mahdi Doroodmand, Fazlolah Eshghi

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hossein Torabi-MonfaredDepartment of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran.
Leila SherafatDepartment of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran.
Mohammad Mahdi DoroodmandDepartment of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran. doroodmand@shirazu.ac.ir.
Fazlolah EshghiDepartment of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detecting humidity have been remained a continuing concern within some important areas such as structural health, food processing, industrial as well as agricultural products. In this study, a novel humidity optical sensor is introduced based on the thermionic emission of tungsten filament using the fluorescent lamp set-up. Estimated blue compliant using a charged coupling device camera in optical image of the tungsten filament was confirmed as an appropriate detection system for relative humidity (RH) sensing. The fabricated optical sensor has wide linear range (2.0-98% RH), improved detection limit (< 5.0% RH), acceptable saturated limit (> 99.0% RH), improved percentage of relative standard deviation (4.18%, n = 2), adequate hysteresis (< 4.0% RH) and a shorter rise time (< 5.0 s), respectively. The mechanism behind this detection system is based on the interaction between H

Identifiers

PMID34518600
PMCPMC8438020

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.