Evidence map›Paper›PMID 34517913›Full record

ArticleInjury epidemiology2021

A firm recommendation: measuring the softness of infant sleep surfaces.

Sheena H Gillani, Gina S Lowell, Kyran P Quinlan

Open access · goldAbstract read
In one paragraph

Article in Injury epidemiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Sheena H GillaniChicago Medical School, Rosalind Franklin University of Medicine and Science, 3333 Green Bay Rd, North Chicago, IL, 60064, USA. sheena.gillani@my.rfums.org.ORCID http://orcid.org/0000-0002-9793-0022
Gina S LowellDepartment of Pediatrics, Rush University Children's Hospital, 1653 W. Congress Pkwy, Chicago, IL, 60612, USA.
Kyran P QuinlanDepartment of Pediatrics, Rush University Children's Hospital, 1653 W. Congress Pkwy, Chicago, IL, 60612, USA.
Rush Children's Hospital · USRosalind Franklin University of Medicine and Science · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundApproximately 3600 sudden unexpected infant deaths (SUID) occur annually in the United States, and a quarter of SUIDs are caused by unintentional suffocation and strangulation in bed, with soft bedding use being a significant risk factor. Therefore, The American Academy of Pediatrics (AAP) recommends infants sleep on a "firm" surface, though neither an objective definition nor national standard has been established. The purpose of this study is to report on the performance of a device that measures mattress softness and to provide quantitative values of softness for various infant sleep surfaces.

methodsIn collaboration with the authors and a national child product safety organization (Kids in Danger), University of Michigan engineering students designed and validated a device that measures the vertical depression (softness) of a simulated 2-month-old's head on a sleep surface. A total of 17 infant sleep surfaces - 14 household surfaces and 3 hospital mattresses - were measured between April 2019 and January 2020. The average softness of each surface was calculated. Surfaces were also measured with soft bedding, which included an infant fleece blanket, and firm and soft pillows.

resultsThe average softness for the 14 household sleep surfaces ranged from 7.4-36.9 mm. The 2019 cribette playard and the 2018 infant spring had similar softness (21 mm) as the 2018 and 2019 adult foam and 2015 sofa. An infant's fleece blanket folded once added an additional 2.3-6.5 mm of softness, folded twice added 4.8-11.6 mm, and folded three times added 11-21.8 mm. Using a firm pillow added 4.0-20.9 mm of softness while using a soft pillow added 24.5-46.4 mm. The softness for the 3 hospital sleep surfaces ranged from 14 to 36.9 mm, with the infant bassinet being the firmest and the pediatrics mattress being the softest.

conclusionsWe found a wide range of softness among sleep surfaces, with some infant mattresses as soft as some adult mattresses. Adding blankets and pillows to mattresses measurably increased softness. Quantifying sleep surface softness will advance our understanding of how softness relates to SUID risk. We hope this new information will further inform safe infant sleep recommendations and improve mattress safety standards nationally.

Indexed as

Mattress firmnessMattress softnessSafe sleepSoft beddingSUID

Identifiers

PMID34517913
PMCPMC8436463
OpenAlexW3173809041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.