Evidence map›Paper›PMID 34517469›Full record

ReviewNeurointervention2021

Silk® Flow Diverter Device for Intracranial Aneurysm Treatment: A Systematic Review and Meta-Analysis.

William A Florez, Ezequiel Garcia-Ballestas, Gabriel Alexander Quiñones-Ossa, Tariq Janjua, Subhas Konar, Amit Agrawal, Luis Rafael Moscote-Salazar

Abstract readReview
In one paragraph

Review in Neurointervention, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Review
  5. Review
  6. Article
  7. The DERIVO®2 Embolization Device in the treatment of ruptured and unruptured intracranial aneurysms: A multicenter analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024
    Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

William A FlorezLatin American Council of Neurocritical Care (CLaNi), Cartagena, Colombia.
Ezequiel Garcia-BallestasLatin American Council of Neurocritical Care (CLaNi), Cartagena, Colombia.
Gabriel Alexander Quiñones-OssaLatin American Council of Neurocritical Care (CLaNi), Cartagena, Colombia.
Tariq JanjuaDepartment of Neurology and Critical Care Medicine, Regions Hospital, Saint Paul, MN, USA.
Subhas KonarDepartment of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India.
Amit AgrawalDepartment of Neurosurgery, All India Institute of Medical Sciences, Madhya Pradesh, India.
Luis Rafael Moscote-SalazarLatin American Council of Neurocritical Care (CLaNi), Cartagena, Colombia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Flow diverters have become a critical instrument for complex aneurysms treatment. However, limited data are currently available regarding short and long-term outcomes for the Silk flow diverter. The objective of the study is to determine neurological prognosis and mortality rates for the Silk flow diversion device used in intracranial aneurysms. A systematic review with meta-analysis was performed using databases. The following descriptors were used for the search: "SILK", "Flow Diverter", "Mortality", and "Prognosis". The following data were extracted: mortality, good functional outcome, Glasgow outcome scale, complete or near-complete occlusion rates, rate of retreatment, and complications (thromboembolic and hemorrhagic complications). A total of 14 studies were selected. Among the 14 studies, 13 were retrospective observational cohort studies and 1 was a prospective observational cohort study. The mortality rate was 2.84%. The clinical good outcomes rate was 93.3%. The poor outcome rate was 6.6%. The overall thromboembolic complication rate was 6.06% (95% confidence interval [CI] 0.00-6.37, P=0.12, I2=3.13%). The total hemorrhagic complication rate was 1.62% (95% CI 0.00-5.34, P=0.28, I2=1.56%). The complete aneurysm occlusion rate was 80.4% (95% CI 8.65-9.38, P<0.0001, I2=9.09%). The Silk diverter device has a good safety and efficacy profile for treating intracranial aneurysms with high complete occlusion rates.

Indexed as

AneurysmCerebrovascular circulationIntracranial aneurysmNeurosurgeryNeurosurgical procedures

Identifiers

PMID34517469
PMCPMC8561040

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.