Evidence map›Paper›PMID 34516524›Full record

Observational studyMedicine2021

Removal of a catheter mount and heat-and-moisture exchanger improves hypercapnia in patients with acute respiratory distress syndrome: A retrospective observational study.

Takaya Shimoda, Motohiro Sekino, Ushio Higashijima, Sojiro Matsumoto, Shuntaro Sato, Rintaro Yano, Takashi Egashira, Hiroshi Araki, Iwasaki Naoya, Suzumura Miki and 4 more

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 3 institutions in 2 countries.

Takaya ShimodaMedical Engineering Equipment Center, Nagasaki University Hospital, Nagasaki, Japan.
Motohiro SekinoDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Ushio HigashijimaDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Sojiro MatsumotoDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Shuntaro SatoClinical Research Center, Nagasaki University Hospital, Nagasaki, Japan.
Rintaro YanoDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Takashi EgashiraDepartment of Intensive Care, Nagasaki Harbor Medical Center, Nagasaki, Japan.
Hiroshi ArakiDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Iwasaki NaoyaDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Suzumura MikiDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Ryo KoyanagiMedical Engineering Equipment Center, Nagasaki University Hospital, Nagasaki, Japan.
Makoto HayashiMedical Engineering Equipment Center, Nagasaki University Hospital, Nagasaki, Japan.
Shintaro KuriharaMedical Engineering Equipment Center, Nagasaki University Hospital, Nagasaki, Japan.
Tetsuya HaraDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Statistical Research (United States) · USNagasaki Medical Center · JPNagasaki University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

abstractTo avoid ventilator-associated lung injury in acute respiratory distress syndrome (ARDS) treatment, respiratory management should be performed at a low tidal volume of 6 to 8 mL/kg and plateau pressure of ≤30 cmH2O. However, such lung-protective ventilation often results in hypercapnia, which is a risk factor for poor outcomes. The purpose of this study was to retrospectively evaluate the effectiveness and safety of the removal of a catheter mount (CM) and using heated humidifiers (HH) instead of a heat-and-moisture exchanger (HME) for reducing the mechanical dead space created by the CM and HME, which may improve hypercapnia in patients with ARDS.This retrospective observational study included adult patients with ARDS, who developed hypercapnia (PaCO2 > 45 mm Hg) during mechanical ventilation, with target tidal volumes between 6 and 8 mL/kg and a plateau pressure of ≤30 cmH2O, and underwent stepwise removal of CM and HME (replaced with HH). The PaCO2 values were measured at 3 points: ventilator circuit with CM and HME (CM + HME) use, with HME (HME), and with HH (HH), and the overall number of accidental extubations was evaluated. Ventilator values (tidal volume, respiratory rate, minutes volume) were evaluated at the same points.A total of 21 patients with mild-to-moderate ARDS who were treated under deep sedation were included. The values of PaCO2 at HME (52.7 ± 7.4 mm Hg, P < .0001) and HH (46.3 ± 6.8 mm Hg, P < .0001) were significantly lower than those at CM + HME (55.9 ± 7.9 mm Hg). Measured ventilator values were similar at CM + HME, HME, and HH. There were no cases of reintubation due to accidental extubation after the removal of CM.The removal of CM and HME reduced PaCO2 values without changing the ventilator settings in deeply sedated patients with mild-to-moderate ARDS on lung-protective ventilation. Caution should be exercised, as the removal of a CM may result in circuit disconnection or accidental extubation. Nevertheless, this intervention may improve hypercapnia and promote lung-protective ventilation.

Indexed as

AgedFemaleHot TemperatureHumansHumidifiersHypercapniaMaleRespiration, ArtificialRespiratory Distress SyndromeRetrospective Studies

Identifiers

PMID34516524
PMCPMC8428744
OpenAlexW3200000870

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.