SynthesisThe Cochrane database of systematic reviews2021
Physiological track-and-trigger/early warning systems for use in maternity care.
Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Physiological track-and-trigger/early warning systems for use in maternity care.The Cochrane database of systematic reviews · 2021Pooled it
- Article
- Bibliometric analysis of scientific research on early obstetric warning system.Journal of education and health promotion · 2025Review
- Development of a national maternity early warning score: centile based score development and Delphi informed escalation pathways.BMJ medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA considerable challenge for maternity care providers is recognising clinical deterioration early in pregnant women. Professional bodies recommend the use of clinical assessment protocols or evaluation tools, commonly referred to as physiological track-and-trigger systems (TTS) or early warning systems (EWS), as a means of helping maternity care providers recognise actual or potential clinical deterioration early. TTS/EWS are clinician-administered (midwife, obstetrician), bedside physiological assessment protocols, charts or tools designed to record routinely assessed clinical parameters; that is, blood pressure, temperature, heart rate, urine output and mental/neurological alertness. In general, these systems involve the application of scores or alert indicators to the observed physiological parameters based on their prespecified limits of normality. The overall system score or alert limit is then used to assist the maternity care provider identify a need to escalate care. This, in turn, may allow for earlier intervention(s) to alter the course of the emerging critical illness and ultimately reduce or avoid mortality and morbidity sequelae.
objectivesTo evaluate the clinical- and cost-effectiveness of maternal physiological TTS/EWS on pregnancy, labour and birth, postpartum (up to 42 days) and neonatal outcomes. SEARCH
methodsWe searched Cochrane Pregnancy and Childbirth's Trials Register (28 May 2021), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP) (7 June 2021), OpenGrey, the ProQuest Dissertations and Theses database (7 June 2021), and reference lists of retrieved studies. SELECTION CRITERIA: We included randomised and quasi-randomised controlled trials (RCTs), including cluster-RCTs, comparing physiological TTS/EWS with no system or another system. Participants were women who were pregnant or had given birth within the previous 42 days, at high risk and low risk for pregnancy, labour and birth, and postpartum complications. DATA COLLECTION AND ANALYSIS: Two review authors (VS and MN) independently assessed all identified papers for inclusion and performed risk of bias assessments. Any discrepancies were resolved through discussion and consensus. Data extraction was also conducted independently by two review authors (VS and MN) and checked for accuracy. We used the summary odds ratio (OR) with 95% confidence intervals (CIs) to present the results for dichotomous data and the mean difference (MD) with 95% CI to present the results for continuous data. MAIN
resultsWe included two studies, a parallel RCT involving 700 women and a stepped-wedge cluster trial involving 536,233 women. Both studies were published in 2019, and both were conducted in low-resource settings. The interventions were the 'Saving Mothers Score' (SMS) and the CRADLE Vital Sign Alert (VSA) device, and both interventions were compared with standard care. Both studies had low or unclear risk of bias on all seven risk of bias criteria. Evidence certainty, assessed using GRADE, ranged from very low to moderate certainty, mainly due to other bias as well as inconsistency and imprecision. For women randomised to TTS/EWS compared to standard care there is probably little to no difference in maternal death (OR 0.80, 95% CI 0.30 to 2.11; 1 study, 536,233 participants; moderate-certainty evidence). Use of TTS/EWS compared to standard care may reduce total haemorrhage (OR 0.36, 95% CI 0.19 to 0.69; 1 study, 700 participants; low-certainty evidence). For women randomised to TTS/EWS compared to standard care there may be little to no difference in sepsis (OR 0.21, 95% CI 0.02 to 1.80; 1 study, 700 participants; low-certainty evidence), eclampsia (OR 1.50, 95% CI 0.74 to 3.03; 2 studies, 536,933 participants; low-certainty evidence) and HELLP (OR 0.21, 95% CI 0.01 to 4.40; 1 study, 700 participants; very low-certainty evidence), and probably little to no difference in maternal admission to the intensive care unit (ICU) (OR 0.78, 95% CI 0.53 to 1.15; 2 studies, 536,933 participants; moderate-certainty evidence). Use of TTS/EWS compared to standard care may reduce a woman's length of hospital stay (MD -1.21, 95% CI -1.78 to -0.64; 1 study, 700 participants; low-certainty evidence) but may result in little to no difference in neonatal death (OR 1.06, 95% CI 0.62 to 1.84; 1 study, 700 participants; low-certainty evidence). Cost-effectiveness measures were not measured in either of the two studies. AUTHORS'
conclusionsUse of TTS/EWS in maternity care may be helpful in reducing some maternal outcomes such as haemorrhage and maternal length of hospital stay, possibly through early identification of clinical deterioration and escalation of care. The evidence suggests that the use of TTS/EWS compared to standard care probably results in little to no difference in maternal death and may result in little to no difference in neonatal death. Both of the included studies were conducted in low-resource settings where the use of TTS/EWS might potentially confer a different effect to TTS/EWS use in high-resource settings. Further high-quality trials in high- and middle-resource settings, as well as in discrete populations of high- and low-risk women, are required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials