Evidence map›Paper›PMID 34513372›Full record

ArticleCureus2021

Constructing an Individualized Middle Cerebral Artery Model Using 3D Printing and Hydrogel for Bypass Training.

Sinem S Ovunc, Mohamed Yassin, Ricky Chae, Adib Abla, Roberto Rodriguez Rubio

Abstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sinem S OvuncNeurological Surgery, University of California San Francisco (UCSF), San Francisco, USA.
Mohamed YassinNeurological Surgery, University of California San Francisco (UCSF), San Francisco, USA.
Ricky ChaeNeurological Surgery, University of California San Francisco (UCSF), San Francisco, USA.
Adib AblaNeurological Surgery, University of California San Francisco (UCSF), San Francisco, USA.
Roberto Rodriguez RubioNeurological Surgery, University of California San Francisco (UCSF), San Francisco, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The importance and complexity of cerebral bypass surgery (CBS) highlight the necessity for intense and dedicated training. Several available training models are yet to satisfy this need. In this technical note, we share the steps to construct a digital imaging and communications in medicine (DICOM)-based middle cerebral artery (MCA) model that is anatomically accurate, resembles handling properties of living tissue, and enables trainers to observe the cerebrovascular anatomy, improve and maintain microsurgical dexterity, and train in the essential steps of CBS. The internal and external molds were created from the geometry of DICOM-based MCA using Fusion 360 software (Autodesk, San Rafael, USA). They were then three-dimension (3D) printed using a polylactic acid filament. The 15% w/v solution of polyvinyl alcohol (PVA) was prepared and injected between the molds. Using five freeze-thaw cycles the solution was converted to tissue-mimicking cryo-gel. The model was then placed in a chloroform bath until the internal mold dissolved. To evaluate the accuracy of the MCA model, selected characteristics were measured and compared with the MCA mesh. The DICOM-based MCA model was produced using 3D printing that was available in the lab and the overall cost was less than $5 per model. The external mold required six and a half hours to be 3D printed, while the internal mold only required 23 minutes. Overall, the time required to 3D print the DICOM-based MCA model was just short of seven hours. The greatest statistically significant difference between the virtual MCA model and the DICOM-based MCA model was found in the length of the pre-bifurcation part of the M1 segment and the total length of the superior bifurcation trunk of M1 and superior branch of M2. The smallest statistically significant difference was found at the diameter of the inferior post-bifurcation trunk of the M1 segment and the diameter at the origin of the artery. This technical report aims to show the construction of a CBS training system involving the DICOM-based MCA model that demonstrates the shape of the vascular tree, resembles the handling/suturing properties of living tissue, and helps set up a homemade training station. We believe that our DICOM-based MCA model can serve as a valuable resource for CBS training throughout the world due to its cost-effectiveness and straightforward construction steps. Moreover, once the DICOM-based MCA model is used with our training station, it may offer an option for trainers to gain and maintain CBS skills despite limitations on time, cost, and space. This work was presented in February 2019 at the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Cerebrovascular Section Annual Meeting held in Honolulu, Hawaii.

Indexed as

immersive technologiesmedical educationself-paced learningsimulationsurgical trainingthree-dimensional (3d) printing

Identifiers

PMID34513372
PMCPMC8405358

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.