Evidence map›Paper›PMID 34513239›Full record

ArticleBiomedical optics express2021

Clinical assessment of W-band spectroscopy for non-invasive detection and monitoring of sustained hyperglycemia.

Aldo Moreno-Oyervides, M Carmen Aguilera-Morillo, María José de la Cruz Fernández, Edurne Lecumberri Pascual, Lucía Llanos Jiménez, Viktor Krozer, Pablo Acedo

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Aldo Moreno-OyervidesDepartment of Electronic Technology, Universidad Carlos III de Madrid, Leganés, 28911 Madrid, Spain.ORCID https://orcid.org/0000-0002-8865-2518
M Carmen Aguilera-MorilloDepartment of Applied Statistics and Operational Research, and Quality, Universitat Politècnica de València, 46022 Valencia, Spain.
María José de la Cruz FernándezInstituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD), Madrid, Spain.
Edurne Lecumberri PascualServicio de Endocrinología y Nutrición, Hospital Universitario Ramón y Cajal, Madrid 28034, Spain.
Lucía Llanos JiménezInstituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD), Madrid, Spain.
Viktor KrozerPhysics Institute, Goethe University Frankfurt am Main, Frankfurt am Main 60438, Germany.
Pablo AcedoDepartment of Electronic Technology, Universidad Carlos III de Madrid, Leganés, 28911 Madrid, Spain.ORCID https://orcid.org/0000-0002-8053-7363
Hospital Universitario Fundación Jiménez Díaz · ESGoethe University Frankfurt · DEHospital Universitario Ramón y Cajal · ESUniversitat Politècnica de València · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

HbA1c is the gold standard test for monitoring medium/long term glycemia conditions in diabetes care, which is a critical factor in reducing the risk of chronic diabetes complications. Current technologies for measuring HbA1c concentration are invasive and adequate assays are still limited to laboratory-based methods that are not widely available worldwide. The development of a non-invasive diagnostic tool for HbA1c concentration can lead to the decrease of the rate of undiagnosed cases and facilitate early detection in diabetes care. We present a preliminary validation diagnostic study of W-band spectroscopy for detection and monitoring of sustained hyperglycemia, using the HbA1c concentration as reference. A group of 20 patients with type 1 diabetes mellitus and 10 healthy subjects were non-invasively assessed at three different visits over a period of 7 months by a millimeter-wave spectrometer (transmission mode) operating across the full W-band. The relationship between the W-band spectral profile and the HbA1c concentration is studied using longitudinal and non-longitudinal functional data analysis methods. A potential blind discrimination between patients with or without diabetes is obtained, and more importantly, an excellent relation (R-squared = 0.97) between the non-invasive assessment and the HbA1c measure is achieved. Such results support that W-band spectroscopy has great potential for developing a non-invasive diagnostic tool for in-vivo HbA1c concentration monitoring in humans.

Identifiers

PMID34513239
PMCPMC8407808
OpenAlexW3182889293

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.