Evidence map›Paper›PMID 34505839›Full record

ArticleJournal of medical Internet research2021

Automated Detection of Acute Myocardial Infarction Using Asynchronous Electrocardiogram Signals-Preview of Implementing Artificial Intelligence With Multichannel Electrocardiographs Obtained From Smartwatches: Retrospective Study.

Changho Han, Youngjae Song, Hong-Seok Lim, Yunwon Tae, Jong-Hwan Jang, Byeong Tak Lee, Yeha Lee, Woong Bae, Dukyong Yoon

Open access · goldAbstract read
In one paragraph

Article in Journal of medical Internet research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Review
  15. A Review of Converging Technologies in eHealth Pertaining to Artificial Intelligence.International journal of environmental research and public health · 2022
    Review
  16. Review
  17. Review
  18. Review
  19. Article
  20. Artificial intelligence for cardiology: from diagnosis to management.Therapeutic advances in cardiovascular disease
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Changho Han *Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Yongin, Republic of Korea.ORCID 0000-0003-4121-5465
Youngjae Song *VUNO Inc, Seoul, Republic of Korea.ORCID 0000-0002-5278-9715
Hong-Seok Lim *Department of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.ORCID 0000-0002-3127-2071
Yunwon TaeVUNO Inc, Seoul, Republic of Korea.ORCID 0000-0002-3845-592X
Jong-Hwan JangDepartment of Biomedical Systems Informatics, Yonsei University College of Medicine, Yongin, Republic of Korea.ORCID 0000-0003-3392-822X
Byeong Tak LeeVUNO Inc, Seoul, Republic of Korea.ORCID 0000-0002-1802-9915
Yeha LeeVUNO Inc, Seoul, Republic of Korea.ORCID 0000-0002-6248-7729
Woong BaeVUNO Inc, Seoul, Republic of Korea.ORCID 0000-0003-3128-9866
Dukyong YoonDepartment of Biomedical Systems Informatics, Yonsei University College of Medicine, Yongin, Republic of Korea.ORCID 0000-0003-1635-8376
Yonsei University · KRAjou University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhen using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored.

objectiveWe aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead-based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power.

methodsWe extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked.

resultsThe performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads-ideally more than 4 leads-is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction.

conclusionsBy developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.

Indexed as

Artificial IntelligenceMyocardial InfarctionAlgorithmsElectrocardiographyHumansRetrospective Studiesartificial intelligenceasynchronous electrocardiogramautomatic diagnosiscardiac healthcardiologydeep learningdigital healthmachine learningmyocardial infarctionsmartwatchestimely diagnosiswearables

Identifiers

PMID34505839
PMCPMC8463948
OpenAlexW3197978269

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.