SynthesisScientific reports2021
Second-generation cryoballoon versus contact force radiofrequency ablation for atrial fibrillation: an updated meta-analysis of evidence from randomized controlled trials.
Synthesis in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Efficacy and Safety of Laser Balloon Versus Irrigated Radiofrequency Ablation as Initial Therapies for Atrial Fibrillation: A Meta-Analysis.Reviews in cardiovascular medicine · 2024Pooled it
- Silent cerebral lesions after catheter ablation for atrial fibrillation using cryoballoon, hotballoon, laserballoon and radiofrequency catheters: a Bayesian network meta-analysis.Frontiers in cardiovascular medicine · 2024Pooled it
- Comparison of cryoballoon and radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023Pooled it
- Sex- and Age-Dependent Outcomes of Cryoablation in Atrial Fibrillation: A 3- and 6-Month Post-Procedural QoL Analysis.Journal of arrhythmia · 2026Article
- Comparative outcomes of manual compression, double-ProGlide and the LaPFOE technique following cryoballoon atrial fibrillation ablation with uninterrupted oral anticoagulants.BMC cardiovascular disorders · 2025Article
- Radiofrequency balloon ablation: 1-year outcomes of the AURORA study.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025Article
- Comparative safety and effectiveness of cryoballoon versus radiofrequency ablation for atrial fibrillation: a systematic review and meta-analysis.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2025Review
- Global Research Progress on Radiofrequency Ablation in Cardiology.Annals of medicine and surgery (2012) · 2025Review
- Advances in Atrial Fibrillation Management: A Guide for General Internists.Journal of clinical medicine · 2024Review
- A meta-analysis and cost-minimization analysis of cryoballoon ablation versus radiofrequency ablation for paroxysmal atrial fibrillation.Journal of arrhythmia · 2024Article
- Early Clinical Outcomes and Advantages of a Novel-Size Adjustable Second-Generation Cryoballoon: A Proof-of-Concept Study.Journal of clinical medicine · 2024Article
- Innovations in atrial fibrillation ablation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023Review
- Efficacy and safety of visually guided laser balloon versus cryoballoon ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis.Frontiers in cardiovascular medicine · 2023Review
- The efficacy and safety of cryoballoon atrial fibrillation ablation in patients with heart failure: A systematic review and meta-analysis.Indian pacing and electrophysiology journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Catheter ablation has been recommended for patients with symptomatic atrial fibrillation (AF), with pulmonary vein isolation being the cornerstone of the ablation procedure. Newly developed technologies, such as cryoballoon ablation with a second-generation cryoballoon (CB2) and the contact force radiofrequency (CF-RF) ablation, have been introduced in recent years to overcome the shortcomings of the widely used RF ablation approach. However, high-quality results comparing CB2 and CF-RF remain controversial. Thus, we conducted this meta-analysis to assess the efficacy and safety between CB2 and CF-RF using evidence from randomized controlled trials (RCTs). Databases including Embase, PubMed, the Cochrane Library, and ClinicalTrials.gov were systematically searched from their date of inception to January 2021. Only RCTs that met the inclusion criteria were included for analysis. The primary outcome of interest was freedom from atrial tachyarrhythmia (AT) during follow-up. Secondary outcomes included procedure-related complications, procedure time and fluoroscopy time. Six RCTs with a total of 987 patients were finally enrolled. No significant differences were found between CB2 and CF-RF in terms of freedom from AT (relative risk [RR] = 1.03, 95% confidence interval [CI] 0.92-1.14, p = 0.616) or total procedural-related complications (RR = 1.25, 95% CI 0.69-2.27, p = 0.457). CB2 treatment was associated with a significantly higher risk of phrenic nerve palsy (PNP) than CF-RF (RR = 4.93, 95% CI 1.12-21.73, p = 0.035). The occurrences of pericardial effusion/tamponade and vascular complications were comparable between the CB2 and CF-RF treatments (RR = 0.41, p = 0.398; RR = 0.82, p = 0.632). In addition, CB2 treatment had a significantly shorter procedure time than CF-RF (weighted mean difference [WMD] = - 20.75 min, 95% CI - 25.44 ~ - 16.05 min, P < 0.001), whereas no difference was found in terms of fluoroscopy time (WMD = 4.63 min, p = 0.179). CB2 and CF-RF treatment are comparable for AF patients regarding freedom from AT and procedure-related complications. Compared to CF-RF, CB2 treatment was associated with a shorter procedure time but a higher incidence of PNP. Further large-scale studies are warranted to compare these two techniques and provide an up-to-date recommendation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.