Evidence map›Paper›PMID 34502983›Full record

ArticlePolymers2021

Application of New Triple Hook-Shaped Conformal Cooling Channels for Cores and Sliders in Injection Molding to Reduce Residual Stress and Warping in Complex Plastic Optical Parts.

Abelardo Torres-Alba, Jorge Manuel Mercado-Colmenero, Juan de Dios Caballero-Garcia, Cristina Martin-Doñate

Abstract read
In one paragraph

Article in Polymers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abelardo Torres-AlbaDepartment of Engineering Graphics, Design and Projects, Campus Las Lagunillas s/n., University of Jaen, Building A3-210, 23071 Jaen, Spain.
Jorge Manuel Mercado-ColmeneroDepartment of Engineering Graphics, Design and Projects, Campus Las Lagunillas s/n., University of Jaen, Building A3-210, 23071 Jaen, Spain.ORCID 0000-0001-8823-4896
Juan de Dios Caballero-GarciaDepartment of Engineering Graphics, Design and Projects, Campus Las Lagunillas s/n., University of Jaen, Building A3-210, 23071 Jaen, Spain.
Cristina Martin-DoñateDepartment of Engineering Graphics, Design and Projects, Campus Las Lagunillas s/n., University of Jaen, Building A3-210, 23071 Jaen, Spain.ORCID 0000-0001-5380-4983

Funding

University of Jaen Plan de Apoyo a la Investigación 2021-2022-ACCION1a POAI 2021-2022: TIC-159
6 · The paper itself

Abstract

The paper presents a new design of a triple hook-shaped conformal cooling channels for application in optical parts of great thickness, deep cores, and high dimensional and optical requirements. In these cases, the small dimensions of the core and the high requirements regarding warping and residual stresses prevent the use of traditional and standard conformal cooling channels. The research combines the use of a new triple hook-shaped conformal cooling system with the use of three independent conformal cooling sub-systems adapted to the complex geometric conditions of the sliders that completely surround the optical part under study. Finally, the new proposed conformal cooling design is complemented with a small insert manufactured with a new Fastcool material located in the internal area of the optical part beside the optical facets. A transient numerical analysis validates the set of improvements of the new proposed conformal cooling system presented. The results show an upgrade in thermal efficiency of 267.10% in comparison with the traditional solution. The increase in uniformity in the temperature gradient of the surface of the plastic part causes an enhancement in the field of displacement and in the map of residual stresses reducing the total maximum displacements by 36.343% and the Von-Mises maximum residual stress by 69.280% in comparison with the results obtained for the traditional cooling system. Additionally, the new design of cooling presented in this paper reduces the cycle time of the plastic part under study by 32.61%, compared to the traditional cooling geometry. This fact causes a very high economic and energy saving in line with the sustainability of a green mold. The improvement obtained in the technological parameters will make it possible to achieve the optical and functional requirements established for the correct operation of complex optical parts, where it is not possible to use traditional cooling channels or standard conformal cooling layouts.

Indexed as

conformal coolingindustrial designinjection moldingmanufacturingnumerical simulationsustainability

Identifiers

PMID34502983
PMCPMC8434027

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked