Evidence map›Paper›PMID 34502572›Full record

ArticleSensors (Basel, Switzerland)2021

Application of Simulated Arms with Real-Time Pressure Monitor in Casting and Splinting by Physiological Sensors.

Hsuan-Kai Kao, Yi-Chao Wu, Chi-Heng Lu, Zhong Hua, Mei-Chuan Chen, Chiu-Ching Tuan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Hsuan-Kai KaoDepartment of Orthopedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.ORCID 0000-0002-1125-0932
Yi-Chao WuInterdisciplinary Program of Green and Information Technology, National Taitung University, Taitung 95092, Taiwan.
Chi-Heng LuDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.ORCID 0000-0001-9348-0899
Zhong HuaDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
Mei-Chuan ChenDepartment of Orthopedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.
Chiu-Ching TuanDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
National Taipei University of Technology · TWChang Gung Memorial Hospital · TWChang Gung University · TWNational Taitung University · TW

Funding

National Taipei University of Technology and Chang Gung Memorial Hospital Joint Research Program funding CGMH-CORPG3I0121
6 · The paper itself

Abstract

In the real condition, the small sensor found it difficult to detect the position of the pressure sore because of casting displacement clinically. The large sensor will detect the incorrect pressure value due to wrinkles without close to arm. Hence, we developed a simulated arm with physiological sensors combined with an APP and a cloud storage system to detect skin pressure in real time when applying a short arm cast or splint. The participants can apply a short arm cast or splint on the simulative arm and the pressure in the cast or splint could be immediately displaced on the mobile application. The difference of pressure values from six pressure detection points of the simulated arm between the intern and the attending physician with 20-year working experience were 22.8%, -7.3%, 25.0%, 8.6%, 38.2%, 49.6%, respectively. It showed that the difference of pressure values in two farthest points, such as radius stab and ulnar styloid, was maximal. The pressures on the skin surface of the short arm cast were within acceptable range. Doctors would obtain reliable reference data and instantly understand the tightness of the swathed cast which would enable them to adjust it at any time to avoid complications.

Indexed as

Radius FracturesHumansSplintscast fixationcasting and splintingfracturesphysiological sensorsradial styloidreal-timesimulated armskin surfaceswathed castulnar styloid

Identifiers

PMID34502572
PMCPMC8434106
OpenAlexW3194318834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked