ArticleSensors (Basel, Switzerland)2021
Application of Simulated Arms with Real-Time Pressure Monitor in Casting and Splinting by Physiological Sensors.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Inverse design of stochastic, voxelated thermo-viscoelastic digital materials.Nature communications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
Abstract
In the real condition, the small sensor found it difficult to detect the position of the pressure sore because of casting displacement clinically. The large sensor will detect the incorrect pressure value due to wrinkles without close to arm. Hence, we developed a simulated arm with physiological sensors combined with an APP and a cloud storage system to detect skin pressure in real time when applying a short arm cast or splint. The participants can apply a short arm cast or splint on the simulative arm and the pressure in the cast or splint could be immediately displaced on the mobile application. The difference of pressure values from six pressure detection points of the simulated arm between the intern and the attending physician with 20-year working experience were 22.8%, -7.3%, 25.0%, 8.6%, 38.2%, 49.6%, respectively. It showed that the difference of pressure values in two farthest points, such as radius stab and ulnar styloid, was maximal. The pressures on the skin surface of the short arm cast were within acceptable range. Doctors would obtain reliable reference data and instantly understand the tightness of the swathed cast which would enable them to adjust it at any time to avoid complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.