Primary Stability in Hip Revision Arthroplasty: Comparison of the Stability of Cementless Fixed Augments on a Modular Acetabular Cage System with and without Cranial Straps.

Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A Beckmann, Jan Philippe Kretzer, Mareike Schonhoff, Sebastian Jäger

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Max JaenischDepartment for Orthopaedics and Trauma Surgery, University Hospital Bonn, 53127 Bonn, Germany.ORCID 0000-0001-5998-0224
Hendrik KohlhofDepartment for Orthopaedics and Trauma Surgery, University Hospital Bonn, 53127 Bonn, Germany.
Dieter Christian WirtzDepartment for Orthopaedics and Trauma Surgery, University Hospital Bonn, 53127 Bonn, Germany.
Frank Alexander SchildbergDepartment for Orthopaedics and Trauma Surgery, University Hospital Bonn, 53127 Bonn, Germany.ORCID 0000-0003-0797-1945
Nicholas A BeckmannLaboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauam Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
Jan Philippe KretzerLaboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauam Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.ORCID 0000-0002-2779-4221
Mareike SchonhoffLaboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauam Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
Sebastian JägerLaboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauam Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
Heidelberg University · DEUniversity Hospital Bonn · DE

Funding

Peter Brehm GmbH, Weisendorf, Germany
6 · The paper itself

Abstract

The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion between the implant components themselves and the bone will be used. Acetabular revision components with a trabecular titanium augment in combination with a large fourth-generation composite left hemipelvis were assembled. These constructs were divided into two groups with (S) and without cranial straps (nS). A total of 1000 cycles was applied at each of three load levels. Relative movements (RM) between the components were measured. Load levels display a significant effect on the amount of RM at all interfaces except between shell/augment. The group assignment appears to have an effect on RM due to significantly differing means at all interfaces. Between bone/shell RM increased as load increased. NS displayed significantly more RM than S. Between shell/augment RM remained constant as load increased. Between shell/cup S showed more RM than nS while both groups' RM increased with load. We conclude a significant increase of primary stability between the shell and the bone through the addition of cranial straps. Relative motion between components (shell/cup) increases through the addition of cranial straps. A clinical impact of this finding is uncertain and requires further investigation. Finally, the cementless fixation of the augment against the rim-portion of the shell appears stable and compares favorably to prior investigation of different fixation techniques.

Indexed as

arthroplastyaugmentcementlesscranial straphipmodularrevision

Identifiers

PMID34501450
PMCPMC8432542
OpenAlexW3197218726

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.