ArticleJournal of clinical medicine2021
Mechanical Thrombectomy in Acute Terminal Internal Carotid Artery Occlusions Using a Large Manually Expandable Stentretriever (Tiger XL Device): Multicenter Initial Experience.
Article in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Radially adjustable stent retriever for mechanical thrombectomy in acute ischemic stroke: Improved first-pass effect with rapid-inflation deflation technique.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Endovascular thrombectomy for distal vessel occlusion stroke: Single-center experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Case Report: Mechanical thrombectomy using stent retriever devices in deep cerebral venous thrombosis: illustrative cases.Frontiers in stroke · 2025Article
- Mechanical thrombectomy using the Nimbus stent-retriever - initial experiences in a single-center observational study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Observational
- Enhancing the First-Pass Effect in Acute Stroke: The Impact of Stent Retriever Characteristics.Journal of clinical medicine · 2024Article
- Combined Aspiration and Stent Retriever Thrombectomy for Distal Carotid Artery Occlusion Using Balloon Guide versus Non-Balloon Guide Catheter.Journal of clinical medicine · 2024Article
- Evolution and advances in endovascular mechanical thrombectomy of cerebral venous sinus thrombosis.International journal of medical sciences · 2024Review
- First-line thrombectomy strategy for carotid terminus occlusions: A systematic review and meta-analysis.World neurosurgery: X · 2023Review
- Evaluation of effectiveness and safety of the large-format pRESET 6-50 thrombectomy stent-retriever in the endovascular treatment of ischemic stroke: real-world experiences from two tertiary comprehensive stroke centers.Frontiers in neurology · 2023Article
- Mechanical thrombectomy of large vessel occlusion using adjustable vs. self-expanding stent-retriever-Comparison of Tigertriever device with stent-like stent-retrievers: A propensity score analysis.Frontiers in neurology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe recently introduced Tigertriever XL Device for treatment of cerebral vessel occlusions combines manual adjustability and maximum length in one device. In this study, we report our initial experience with the Tigertriever XL in terminal ICA occlusions.
methodsRetrospective multicenter analysis of acute terminal ICA occlusions treated by mechanical thrombectomy using the Tigertriever XL Device.
results23 patients were treated using the Tigetriever XL due to an acute occlusion of the terminal ICA. The overall successful reperfusion rate after a median of two maneuvers using the Tigertriever XL Device was 78.3% (mTICI 2b-3). In 43.5% (10/23) additional smaller devices were applied to treat remaining occlusions in downstream territories, which resulted in a final successful reperfusion rate of 95.7%. Device related complications did not occur. Two symptomatic intracerebral hemorrhages (sICH) were observed.
conclusionsThe Tigertriever XL Device might be a helpful tool in the treatment of ICA terminus occlusions with large clot burden resulting in high reperfusion rates. This is mainly related to the manual adjustability of the device combined with the maximum length.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.