Evidence map›Paper›PMID 34501040›Full record

ArticleMaterials (Basel, Switzerland)2021

Vertical Discrepancy in Height of Morse Cone Abutments Submitted to Different Torque Forces.

Bruno Q S Cordeiro, Carlos Fernando de Almeida Barros Mourão, Waldimir R Carvalho, Edgard M Fonseca, Pietro Montemezzi, Kayvon Javid, Cintia C P Martins, Valquiria Quinelato, Mylena D Moreno, Priscila L Casado

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Evaluation of Stress Distribution and Force in External Hexagonal Implant: A 3-D Finite Element Analysis.International journal of environmental research and public health · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Bruno Q S CordeiroGraduate Program in Dentistry, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Carlos Fernando de Almeida Barros MourãoClinical Research Unit of the Antonio Pedro Hospital, Universidade Federal Fluminense, Niterói 24033-900, RJ, Brazil.ORCID 0000-0001-5775-0222
Waldimir R CarvalhoImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Edgard M FonsecaImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Pietro MontemezziIndependent Researcher, 24128 Bergamo, Italy.
Kayvon JavidGraduate Program in Dentistry, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.ORCID 0000-0002-8404-6940
Cintia C P MartinsImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Valquiria QuinelatoImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.ORCID 0000-0001-5923-9364
Mylena D MorenoImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Priscila L CasadoImplant Dentistry Department, Dentistry School, Universidade Federal Fluminense, Niteroi 24020-140, RJ, Brazil.
Universidade Federal Fluminense · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study aimed to evaluate the influence of manual torque (10 Ncm) versus clinical torque (30 Ncm), which is recommended by the manufacturer, on the total length of morse cone implant abutments. Twenty specimens were prepared and distributed into two groups: group 1 with ten analogs for morse cone type implant, and group 2 with ten morse type implants, size 4.3 × 15 cm. In each group, the distance between the implant platform to the top of the prosthetic abutment (abutment height) was measured and subjected to a torque of 10 Ncm. Then, the 30 Ncm torque was applied to the same abutment, and abutment height was measured. The distance between the top of the abutment and the implant/analog base was measured. In order to verify the clinical reproducibility of the experiment, comparisons between the abutment height of the analog at 10 Ncm and the implant at 30 Ncm were performed, showing a greater discrepancy in torque for the 10 Ncm analog (

Indexed as

abutmentimplant-supported prosthesismorse conetorque

Identifiers

PMID34501040
PMCPMC8434443
OpenAlexW3197395213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked