Article in Mikrochimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Felismina T C MoreiraBioMark@ISEP, School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal. ftm@isep.ipp.pt.ORCID http://orcid.org/0000-0003-4237-8952
Barbara P CorreiaBioMark@ISEP, School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal.
Mariana P SousaBioMark@ISEP, School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal.
Goreti F SalesCEB, Centre of Biological Engineering, Minho University, Braga, Portugal.

Funding

ERA-NET FCT/JPND cofund, Oligomer-Focused Screening and Individualized Therapeutics to target Neurodegenerative DisordersPOCTEP 0624_2IQBIONEURO_6_E, Impulso de una red de I+i en química biológica para diagnóstico y tratamiento de enfermedades neurológicas EP - INTERREG V A España Portugal (POCTEP).
6 · The paper itself

Abstract

An innovative sensing assay is described for point-of-care (PoC) quantification of a biomarker of Alzheimer's disease, amyloid β-42 (Aβ-42). This device is based on a cellulose paper-dye test strip platform in which the corresponding detection layer is integrated by applying a molecularly imprinted polymer (MIP) to the cellulose paper surface. Briefly, the cellulose paper is chemically modified with a silane to subsequently apply the MIP detection layer. The imprinting process is confirmed by the parallel preparation of a control material, namely a non-imprinted polymer (NIP). The chemical changes of the surface were evaluated by Fourier transform infrared spectroscopy (FTIR), contact angle, and thermogravimetric analysis (TG). Proteins and peptides can be quantified by conventional staining methods. For this purpose, Coomassie blue (CB) was used as a staining dye for the detection and quantification of Aβ-42. Quantitative determination is made possible by taking a photograph and applying an appropriate mathematical treatment to the color coordinates provided by the ImageJ program. The MIP shows a linear range between 1.0 ng/mL and 10 μg/mL and a detection limit of 0.71 ng/mL. Overall, this cellulose-based assay is suitable for the detection of peptides or proteins in a sample by visual comparison of color change. The test strip provides a simple, instrument-free, and cost-effective method with high chemical stability, capable of detecting very small amounts of peptides or proteins in a sample, and can be used for the detection of any (bio)molecule of interest.

Indexed as

Amyloid beta-PeptidesAnimalsAntibodies, ImmobilizedBiomarkersCattleCelluloseColorimetryColoring AgentsImmunoassayLimit of DetectionMolecularly Imprinted PolymersPeptide FragmentsPoint-of-Care TestingRosaniline DyesAmyloid beta-Peptidesamyloid beta-protein (1-42)Antibodies, ImmobilizedBiomarkersCelluloseColoring AgentsCoomassie blueMolecularly Imprinted PolymersPeptide FragmentsRosaniline DyesCellulose substratesColorimetric measurementsMolecularly imprinted polymersNaked-eye detectionTest strips

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked