ReviewMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2022
Utility of 4D Flow MRI in Thoracic Aortic Diseases: A Literature Review of Clinical Applications and Current Evidence.
Review in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Evaluation of Blood Flow Energy Loss before and after Endovascular Aneurysm Repair Using Four-dimensional Flow MR Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2026Article
- Quantitative Evaluation of Carotid Artery Stenosis by Multi-VENC 4D Flow MRI: Incorporating Turbulent Kinetic Energy for Clinical Validity.Journal of magnetic resonance imaging : JMRI · 2025Article
- Impact of Residual Intimal Flap Displacement Post-TEVAR on TBAD Haemodynamics in Compliant, Patient-specific CFD Simulations Informed by MRI.Annals of biomedical engineering · 2025Article
- Multiscale structure and function of the aortic valve apparatus.Physiological reviews · 2024Review
- Porto-mesenteric four-dimensional flow MRI: a novel non-invasive technique for assessment of gastro-oesophageal varices.Insights into imaging · 2024Article
- Advantages of Photon-Counting Detector CT in Aortic Imaging.Tomography (Ann Arbor, Mich.) · 2023Review
- Early clinical outcomes and molecular smooth muscle cell phenotyping using a prophylactic aortic arch replacement strategy in Loeys-Dietz syndrome.The Journal of thoracic and cardiovascular surgery · 2023Article
- Machine Learning-Based Segmentation of the Thoracic Aorta with Congenital Valve Disease Using MRI.Bioengineering (Basel, Switzerland) · 2023Article
- 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023Review
- Radiomics-based aortic flow profile characterization with 4D phase-contrast MRI.Frontiers in cardiovascular medicine · 2023Article
- 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications.La Radiologia medica · 2022Review
- Evaluating the Haemodynamic Performance of Endografts for Complex Aortic Arch Repair.Bioengineering (Basel, Switzerland) · 2022Review
- Aortic regurgitation: A multimodality approach.Journal of clinical ultrasound : JCU · 2022Review
- 4D Flow MR Imaging of the Left Atrium: What is Non-physiological Blood Flow in the Cardiac System?Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022Article
- Why 4D Flow MRI? Real Advantages.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022Article
- Clinical Application of 4D Flow MR Imaging for the Abdominal Aorta.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Despite the recent technical developments, surgery on the thoracic aorta remains challenging and is associated with significant mortality and morbidity. Decisions about when and if to operate are based on a balance between surgical risk and the hazard of aortic rupture. These decisions are sometimes difficult in elective cases of thoracic aortic diseases, including aneurysms and dissections. Abnormal wall stress derived from flow alterations influences disease progression. Therefore, a better understanding of the complex hemodynamic environment inside the aortic lumen will facilitate patient-specific risk assessments of complications, which enable clinicians to provide timely prophylactic interventions. Time-resolved 3D phase-contrast (4D flow) MRI has many advantages for the in vivo assessment of flow dynamics. Recent developments in 4D flow imaging techniques has led to significant advances in our understanding of physiological flow dynamics in healthy subjects and patients with thoracic aortic diseases. In this clinically focused review of thoracic aortic diseases, we demonstrate the clinical advances acquired with 4D flow MRI from published studies. We provide a systematic overview of key evidences and considerations regarding normal thoracic aortas, thoracic aortic aneurysms, aortic dissections, and thoracic aortas with prosthetic graft replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials