Evidence map›Paper›PMID 34495448›Full record

ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2021

Transcatheter aortic valve replacement: impact of pre-procedural FEops HEARTguide assessment on device size selection in borderline annulus size cases.

J Halim, J Brouwer, M Lycke, M J Swaans, J Van der Heyden

Abstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

J HalimDepartment of Cardiology, Sint-Jan Hospital Bruges, Bruges, Belgium. j_halim@hotmail.com.
J BrouwerDepartment of Cardiology, St. Antonius Hospital Nieuwegein, Nieuwegein, The Netherlands.
M LyckeDepartment of Cardiology, Sint-Jan Hospital Bruges, Bruges, Belgium.
M J SwaansDepartment of Cardiology, St. Antonius Hospital Nieuwegein, Nieuwegein, The Netherlands.
J Van der HeydenDepartment of Cardiology, Sint-Jan Hospital Bruges, Bruges, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe aim of this study is to evaluate device size selection in patients within the borderline annulus size range undergoing transcatheter aortic valve replacement (TAVR) and to assess if pre-procedural patient-specific computer simulation will lead to the selection of a different device size than standard of care.

backgroundIn TAVR, appropriate device sizing is imperative. In borderline annulus size cases no standardised technique for tailored device size selection is currently available. Pre-procedural patient-specific computer simulation can be used, predicting the risk for paravalvular leakage (PVL) and need for permanent pacemaker implantation (PPI).

methodsIn this multicentre retrospective study, 140 patients in the borderline annulus size range were included. Hereafter, device size selection was left to the discretion of the operator. After TAVR, in 24 of the 140 patients, patient-specific computer simulation calculated the most appropriate device size expected to give the lowest risk for PVL and need for PPI. In these 24 patients, device size selection based on patient-specific computer simulation was compared with standard-of-care device size selection relying on a standardised matrix (Medtronic).

resultsIn a significant proportion of the 140 patients (26.4%) a different device size than recommended by the matrix was implanted. In 10 of the 24 patients (41.7%) in whom a computer simulation was performed, a different device size was recommended than by means of the matrix.

conclusionsDevice size selection in patients within the borderline annulus size range is still ambiguous. In these patients, patient-specific computer simulation is feasible and can contribute to a more tailored device size selection.

Indexed as

Aortic stenosisBorderline annulus sizeComputed tomographyPatient-specific computer simulationTranscatheter aortic valve replacement

Identifiers

PMID34495448
PMCPMC8630271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials