Evidence map›Paper›PMID 34495390›Full record

ArticleLung2021

Cone Beam CT Guidance Improves Transbronchial Lung Cryobiopsy Safety.

Bryan S Benn, Arthur Oliver Romero, Hasnain Bawaadam, Nathaniel Ivanick, Mendy Lum, Ganesh Krishna

Abstract read
PubMed Publisher
In one paragraph

Article in Lung, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
2.3field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Yield and safety of different biopsy types in interstitial lung disease: a systematic review and meta-analysis.European respiratory review : an official journal of the European Respiratory Society · 2026
    Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Bryan S BennDivision of Pulmonary and Critical Care Medicine, Department of Medicine, Medical College of Wisconsin, 8701 W Watertown Plank, Milwaukee, WI, 53226, USA. bbenn@mcw.edu.ORCID 0000-0002-1136-8287
Arthur Oliver RomeroDivision of Pulmonary, Critical Care, Allergy and Sleep Medicine, Department of Medicine, University of California, San Francisco, CA, USA.
Hasnain BawaadamDivision of Pulmonary, Critical Care, Allergy and Sleep Medicine, Department of Medicine, University of California, San Francisco, CA, USA.
Nathaniel IvanickDivision of Pulmonary, Critical Care, Allergy and Sleep Medicine, Department of Medicine, University of California, San Francisco, CA, USA.
Mendy LumRespiratory Care Services, El Camino Health, Mountain View, CA, USA.
Ganesh KrishnaDivision of Pulmonary, Critical Care, Allergy and Sleep Medicine, Department of Medicine, University of California, San Francisco, CA, USA.
University of California, San Francisco · USEl Camino Hospital · USMedical College of Wisconsin · USRoswell Park Comprehensive Cancer Center · USUniversity of Nevada, Las Vegas · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDetermining the cause of diffuse parenchymal lung disease (DPLD) is challenging. While surgical lung biopsy has been the standard approach, transbronchial lung cryobiopsy (TBLC) represents a minimally invasive alternative with an acceptable safety profile and reasonable accuracy. In this study, we prospectively assessed whether the use of cone beam CT (CBCT) coupled with a novel bronchoscope holder and prophylactic administration of vasoconstricting medications decreases potential complications and improves diagnostic accuracy when performing TBLC.

methods33 patients presenting for evaluation of newly diagnosed DPLD were enrolled. Demographic data, pulmonary function values, chest imaging pattern, procedural information, and diagnosis were recorded.

resultsMean patient age was 67, with the majority Caucasian (n = 26, 79%) and male (n = 20, 61%). Mean pulmonary function values revealed restrictive lung disease (76 ± 14% predicted) and diffusing capacity impairment (52 ± 16%). A non-usual interstitial pneumonia imaging pattern was commonly seen (n = 20, 61%). CBCT guided TBLC was performed in one lobe (n = 29, 88%) or two lobes (n = 4, 12%) with mean probe-to-pleura distance of 4.2 ± 1.3 mm. No peri or post procedural complications occurred. 32 patients (97%) received a histological diagnosis with a final multidisciplinary conference diagnosis possible for 32 (97%).

conclusionCBCT guided TBLC coupled with a novel articulating scope holder and prophylactic phenylephrine administration has the potential to increase safety and diagnostic yield for patients with newly identified DPLD. Future studies comparing different aspects of this approach in isolation and with other modalities have the potential to refine this procedure to improve patient care.

Indexed as

BronchoscopyLung Diseases, InterstitialBiopsyCone-Beam Computed TomographyHumansLungMaleCone beam CTDiffuse parenchymal lung diseaseInterstitial lung diseaseTransbronchial lung cryobiopsy

Identifiers

PMID34495390
OpenAlexW3197209174

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.