Evidence map›Paper›PMID 34491456›Full record

ArticleJournal of experimental orthopaedics2021

Biomechanics of a calcar loading and a shortened tapered femoral stem: Comparative in-vitro testing of primary stability and strain distribution.

Tobias Freitag, Ralf Bieger, Hartmuth Kiefer, Daniel Dornacher, Heiko Reichel, Anita Ignatius, Lutz Dürselen

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tobias FreitagDepartment of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany. tobias.freitag@rku.de.
Ralf BiegerDepartment of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany.
Hartmuth KieferDepartment of Trauma and Orthopaedic Surgery, Lukas Hospital, Buende, Germany.
Daniel DornacherDepartment of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany.
Heiko ReichelDepartment of Orthopaedic Surgery, Ulm University Medical Centre, Oberer Eselsberg 45, 89081, Ulm, Germany.
Anita IgnatiusInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre, Ulm University Medical Centre, Helmholtzstr. 14, 89081, Ulm, Germany.
Lutz DürselenInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre, Ulm University Medical Centre, Helmholtzstr. 14, 89081, Ulm, Germany.

Funding

aesculap implant systems P711
6 · The paper itself

Abstract

purposeThe most common femoral short stems available on the market can, in principle, be divided with regard to their anchoring concepts into a calcar loading and a shortened tapered design. The purpose of this study was to compare the primary stability and stress-shielding of two short stems, which correspond to these two different anchoring concepts.

methodsUsing seven paired fresh frozen human cadaver femurs, primary axial and rotational stabilities under dynamic load (100-1600 N) were evaluated by miniature displacement transducers after 100,000 load cycles. Changes in cortical strains were measured before and after implantation of both stem types to detect implant-specific load transmission and possible stress-shielding effects.

resultsReversible and irreversible micromotions under dynamic load displayed no significant differences between the two implants. Implantation of either stem types resulted in a reduction of cortical strains in the proximal femur, which was less pronounced for the calcar loading implant.

conclusionsBoth short stems displayed comparable micromotions far below the critical threshold above which osseointegration may disturbed. Neither short stem could avoid proximal stress-shielding. This effect was less pronounced for the calcar loading short stem, which corresponds to a more physiological load transmission.

Indexed as

CadaverMechanical stressMetaphysealMicromotionsPrimary stabilityShort stemStress-shieldingTotal hip arthroplasty

Identifiers

PMID34491456
PMCPMC8423873

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.