Evidence map›Paper›PMID 34491286›Full record

ArticleTranslational vision science & technology2021

Fluctuations of Steady-State Accommodation Is a Marker for Screening Spasm of Near Reflex.

Shrikant R Bharadwaj, Chandrika Ravisankar, Saujanwita Roy, PremNandhini Satgunam

Abstract read
In one paragraph

Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shrikant R BharadwajBrien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
Chandrika RavisankarProf Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.
Saujanwita RoyBrien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
PremNandhini SatgunamBrien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the utility of root mean squared (RMS) deviations of steady-state accommodation as a noncycloplegic marker for spasm of near reflex (SNR) vis-à-vis regular refractive errors. Methods: Binocular steady-state responses of accommodation, pupil, and vergence of 20 patients with accommodative spasm subtype of SNR (SNR-A; 9-23 years) and 91 with regular refractive errors (29 emmetropes, 41 myopes, 21 hyperopes; 19-38 years) was recorded in the uncorrected refractive error state for 120 seconds using a dynamic (50 frames per second), infrared photorefractor. Mean and RMS deviation of raw data was calculated for three 20-second-long epochs and their diagnostic utility was determined using standard ROC curves. Results: RMS deviations of accommodation increased with mean refractive error in SNR-A (y = -0.23x + 0.38; r2 = 0.69; P < 0.001) and regular refractive error (y = -0.02x + 0.10; r2 = 0.14; P = 0.002) cohorts, albeit with steeper slope and higher y-intercept in the former rather than the latter cohort. RMS deviation of 0.19D reliably distinguished SNR-A from regular refractive errors with a sensitivity and specificity of 95.2% and 92.2%, respectively [mean (±1 SEM) area under ROC curve: 0.98 ± 0.01]. The sensitivity, specificity, and area under ROC curve for RMS deviations of pupil (66.7%, 80%, and 0.70 ± 0.09) and vergence (52.4%, 84.6%, and 0.68 ± 0.08) were smaller than accommodation. Conclusions: RMS deviations of steady-state accommodation is a robust noncycloplegic marker for differentiating SNR-A from regular refractive errors. Pupil and vergence fluctuations have limited utility in this regard. Translational Relevance: RMS deviations of accommodation may be easily obtained using commercial photorefractors, and the cut-off values reported herein may be implemented to identify SNR-A during refractive error screening.

Indexed as

Accommodation, OcularMyopiaEmmetropiaHumansReflexSpasm

Identifiers

PMID34491286
PMCPMC8431981

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.