ArticleMikrochimica acta2021
One-step synthesis of N, S-doped carbon dots with orange emission and their application in tetracycline antibiotics, quercetin sensing, and cell imaging.
Article in Mikrochimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 47 citations in OpenAlex.
- Pharmaceutical residues in food samples: occurrence, toxicity, fluorescence quenching mechanisms, and analysis using carbon dot-based fluorescent probes.RSC advances · 2026Review
- Carbon dot-based fluorescent sensors for pharmaceutical detection: Current innovations, challenges, and future prospects.Heliyon · 2024Review
- Construction of ratiometric fluorescence sensor and test strip with smartphone based on dual-emission carbon dots for the specific detection of chlortetracycline.Analytical and bioanalytical chemistry · 2022Article
- Carbon quantum dots with blue/near infrared emissions for ratiometric fluorescent lornoxicam sensing and bio-imaging.Mikrochimica acta · 2022Article
- Transforming waste into value: pomelo-peel-based nitrogen-doped carbon dots for the highly selective detection of tetracycline.RSC advances · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Water soluble N, S-doped carbon dots (N, S-CDs) with orange emission were synthesized from basic fuchsin and sulfosalicylic acid by the typical hydrothermal route. Based on the inner filter effect (IFE), the prepared N, S-CDs can be innovatively developed as an effective "signal-off" multifunctional sensing platform for sensitive determination of tetracycline antibiotics (for example, chlortetracycline (CTC)) and quercetin. The proposed sensor was utilized to realize the determination of CTC in water and milk samples and quercetin in beer sample (λex = 375 nm, λem = 605 nm) with satisfactory recoveries and relative standard deviations (RSD). The linear range and detection limit (LOD) of CTC is 1.24-165 μM and 32.36 nM, respectively. For quercetin, the linear ranges are 0.98-34 μM and 34-165 μΜ, and the LOD is 6.87 nM (3σ/m). By virtue of the good biocompatibility and long-wavelength emission, N, S-CDs were also used in the imaging of oocystis cells and yeast cells, which demonstrated promising applicability for bio-imaging and sensing. In this paper, N, S-doped carbon dots (N, S-CDs) with orange emission (λem = 605 nm) were synthesized from basic fuchsin and sulfosalicylic acid. Based on the inner filter effect (IFE), the prepared N, S-CDs can be innovatively developed as an effective "signal-off" multifunctional sensing platform for the sensing of tetracycline antibiotics (for example: chlortetracycline (CTC)) and quercetin. The sensor has been successfully applied to the determination of CTC in water and milk samples and quercetin in beer sample (λex = 375 nm, λem = 605 nm). The linear range and detection limit (LOD) of CTC is 1.24-165 μM and 32.36 nM respectively. For quercetin, the linear ranges are 0.98-34 μM and 34-165 μΜ, and the LOD is 6.87 nM (3σ/m). In addition, due to the characteristics of good biocompatibility and long-wavelength emission, the N, S-CDs were also used in the imaging of oocystis cells and yeast cells, which demonstrated promising applicability for bioimaging and sensing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.