Evidence map›Paper›PMID 34490067›Full record

ArticleBiomedical engineering letters2021

Stabilizing breathing pattern using local mechanical vibrations: comparison of deterministic and stochastic stimulations in rodent models of apnea of prematurity.

Dean Zeldich, Samer Bou Jawde, Jacob Herrmann, Leen Arnaout, Meghan Griffin, Noam Grunfeld, Yu Zhang, Ramaswamy Krishnan, Erzsébet Bartolák-Suki, Béla Suki

Open access · bronzeAbstract read
In one paragraph

Article in Biomedical engineering letters, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Dean ZeldichDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Samer Bou JawdeDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Jacob HerrmannDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Leen ArnaoutDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Meghan GriffinDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Noam GrunfeldDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Yu ZhangDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Ramaswamy KrishnanDepartment of Emergency Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA USA.
Erzsébet Bartolák-SukiDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Béla SukiDepartment of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.ORCID 0000-0002-9720-1006
Boston University · USBeth Israel Deaconess Medical Center · US

Funding

A multi-scale computational model of the extracellular matrix of the lungU01HL139466 · NHLBI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI SUKI, BELA · 2018 to 2022
$3.9M
Iowa Lung Imaging Training ProgramT32HL144461 · NHLBI · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED, REINHARDT, JOSEPH M · 2019 to 2023
$1.6M
NHLBI NIH HHS T32 HL144461NHLBI NIH HHS U01 HL139466
6 · The paper itself

Abstract

Mechanical stimulation has been shown to reduce apnea of prematurity (AOP), a major concern in preterm infants. Previous work suggested that the underlying mechanism is stochastic resonance, amplification of a subthreshold signal by stochastic stimulation. We hypothesized that the mechanism behind the reduction of apnea length may not be a solely stochastic phenomenon, and suggest that a purely deterministic, non-random mechanical stimulation could be equally as effective. Mice and rats were anesthetized, tracheostomized, and mechanically ventilated to halt spontaneous breathing. Two miniature motors controlled by a microcontroller were attached around the abdomen. Ventilation was paused, stimulations were applied, and the time to the rodent's first spontaneous breath (T) was measured. Six spectrally different signals were compared to one another and the no-stimulation control in mice. The most successful deterministic stimulation (D) at reducing apnea was then compared to a pseudo-random noise (PRN) signal of comparable amplitude and frequency. CO SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13534-021-00203-x.

Indexed as

BreathingMechanotransductionMousePremature infantRat

Identifiers

PMID34490067
PMCPMC8409477
OpenAlexW3196303389

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.