Evidence map›Paper›PMID 34487310›Full record

ArticleThe international journal of cardiovascular imaging2022

Evaluation of complex congenital heart disease with prospective ECG-gated cardiac CT in a single heartbeat at low tube voltage (70 kV) and adaptive statistical iterative reconstruction in infants: a single center experience.

Serap Baş, Utku Alkara, Bahruz Aliyev

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 7 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Serap BaşGaziosmanpaşa Hospital, Department of Radiology, Istanbul Yeni Yuzyil University, Merkez Mah. Çukurçeşme Cad. No:51 Gaziosmapaşa, 34245, Istanbul, Turkey. serapbas579@gmail.com.ORCID http://orcid.org/0000-0002-3607-0620
Utku AlkaraGaziosmanpaşa Hospital, Department of Radiology, Istanbul Yeni Yuzyil University, Merkez Mah. Çukurçeşme Cad. No:51 Gaziosmapaşa, 34245, Istanbul, Turkey.ORCID http://orcid.org/0000-0002-4574-2767
Bahruz AliyevGaziosmanpaşa Hospital, Department of Pediatric Cardiology, Istanbul Yeni Yuzyil University, Istanbul, Turkey.ORCID http://orcid.org/0000-0002-8689-7693
Istanbul Yeni Yüzyıl University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study is to evaluate the radiation dose, image quality, and diagnostic accuracy of prospective ECG-gated cardiac CT at 70 kV and adaptive statistical iterative reconstruction (ASIR), with a single source, 512 slice MDCT in the diagnosis of complex congenital heart disease in infants. We retrospectively evaluated 47 infants (ages 1 day to 353 days) with prospective ECG-gated cardiac CT that was performed on a single source 512 slice CT at low tube voltage (70 kV) using a wide detector aperture, adaptive statistical iterative reconstruction algorithm (ASIR), and specific reconstruction software reducing coronary motion artifacts (SnapShot Freeze). All cardiac images were obtained during the first pass of contrast material through the anatomic structures of interest and the targets for the center of the acquisition window were set 45% of the R-R interval during one cardiac cycle without sedation and breath-hold. The median effective dose measured in our study was 0.64 ± 0.16 mSv. The average subjective overall image quality score was 4.34 ± 0.31 (range 3-5). For the determination of objective image quality, Mean Noise (HU), SNR, and CNR values ​​emerged as 20.8, 28.7(for pulmonary artery), and 27.1, respectively. Diagnostic accuracy was 100% for the main purposes for the main clinical indication. During cardiac CT examination, pathologies in addition to cardiac anomalies were found in 9/47 of cases (7 severe airway obstructions,1 posterior diaphragmatic hernia, 1 vertebral anomaly). Prospective ECG-gated cardiac CT scan at 70 kV and ASIR in infants with complex CHD provides low radiation dose (submillisievert) in a single heartbeat with a good objective and subjective image quality. It also provides important benefits in the diagnosis of additional pathology.

Indexed as

Heart Defects, CongenitalTomography, X-Ray ComputedCoronary AngiographyElectrocardiographyHeart RateHumansInfantPredictive Value of TestsProspective StudiesRadiation DosageRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesCardiac CTComplex congenital heart diseaseInfantsLow-tube voltageProspective ECG-gated

Identifiers

PMID34487310
OpenAlexW3198130221

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked