Evidence map›Paper›PMID 34487258›Full record

ArticleThe ultrasound journal2021

Comparing accuracy of bedside ultrasound examination with physical examination for detection of pleural effusion.

Michael H Walsh, Kang X Zhang, Emily J Cox, Justin M Chen, Nicholas G Cowley, Christopher J Oleynick, Leo M Smyth, Irene W Y Ma

Open access · goldAbstract read
In one paragraph

Article in The ultrasound journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Recent advancements in critical care: Part I.Indian journal of anaesthesia · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Michael H WalshDivision of General Internal Medicine, University of Calgary, Calgary, AB, Canada.
Kang X ZhangProvidence Health Care, Providence Internal Medicine Residency Spokane, Spokane, WA, USA.
Emily J CoxProvidence Health Care, Providence Medical Research Center, Spokane, WA, USA.
Justin M ChenProvidence Health Care, Providence Internal Medicine Residency Spokane, Spokane, WA, USA.
Nicholas G CowleyProvidence Health Care, Providence Internal Medicine Residency Spokane, Spokane, WA, USA.
Christopher J OleynickDivision of General Internal Medicine, University of Calgary, Calgary, AB, Canada.
Leo M SmythDivision of General Internal Medicine, University of Alberta, Edmonton, AB, Canada.
Irene W Y MaDivision of General Internal Medicine, University of Calgary, Calgary, AB, Canada. ima@ucalgary.ca.ORCID http://orcid.org/0000-0002-7580-0171
Providence Health & Services · USUniversity of Calgary · CAUniversity of Alberta · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn detecting pleural effusion, bedside ultrasound (US) has been shown to be more accurate than auscultation. However, US has not been previously compared to the comprehensive physical examination. This study seeks to compare the accuracy of physical examination with bedside US in detecting pleural effusion.

methodsThis study included a convenience sample of 34 medical inpatients from Calgary, Canada and Spokane, USA, with chest imaging performed within 24 h of recruitment. Imaging results served as the reference standard for pleural effusion. All patients underwent a comprehensive lung physical examination and a bedside US examination by two researchers blinded to the imaging results.

resultsPhysical examination was less accurate than US (sensitivity of 44.0% [95% confidence interval (CI) 30.0-58.8%], specificity 88.9% (95% CI 65.3-98.6%), positive likelihood (LR) 3.96 (95% CI 1.03-15.18), negative LR 0.63 (95% CI 0.47-0.85) for physical examination; sensitivity 98% (95% CI 89.4-100%), specificity 94.4% (95% CI 72.7-99.9%), positive LR 17.6 (95% CI 2.6-118.6), negative LR 0.02 (95% CI 0.00-0.15) for US). The percentage of examinations rated with a confidence level of 4 or higher (out of 5) was higher for US (85% of the seated US examination and 94% of the supine US examination, compared to 35% of the PE, P < 0.001), and took less time to perform (P < 0.0001).

conclusionsUS examination for pleural effusion was more accurate than the physical examination, conferred higher confidence, and required less time to complete.

Indexed as

Physical examinationPleural effusionPoint-of-care ultrasoundUltrasound

Identifiers

PMID34487258
PMCPMC8421481
OpenAlexW3196466879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.