Measurement error using a SeeMaLab structured light 3D scanner against a Microscribe 3D digitizer.

Dolores Messer, Michelle S Svendsen, Anders Galatius, Morten T Olsen, Vedrana A Dahl, Knut Conradsen, Anders B Dahl

Open access · goldAbstract read
In one paragraph

Article in PeerJ, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Dolores MesserDepartment of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark.
Michelle S SvendsenGlobe Institute, University of Copenhagen, Copenhagen, Denmark.
Anders GalatiusDepartment of Bioscience, Aarhus University, Roskilde, Denmark.
Morten T OlsenGlobe Institute, University of Copenhagen, Copenhagen, Denmark.
Vedrana A DahlDepartment of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark.
Knut ConradsenDepartment of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark.
Anders B DahlDepartment of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark.
Technical University of Denmark · DKUniversity of Copenhagen · DKAarhus University · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGeometric morphometrics is a powerful approach to capture and quantify morphological shape variation. Both 3D digitizer arms and structured light surface scanners are portable, easy to use, and relatively cheap, which makes these two capturing devices obvious choices for geometric morphometrics. While digitizer arms have been the "gold standard", benefits of having full 3D models are manifold. We assessed the measurement error and investigate bias associated with the use of an open-source, high-resolution structured light scanner called SeeMaLab against the popular Microscribe 3D digitizer arm. METHODOLOGY: The analyses were based on 22 grey seal (

resultsSimilar precision was obtained with both devices. If landmarks that were identified as less clearly defined and thus harder to place were omitted, the scanner pipeline would achieve higher precision than the digitizer. Between-operator error was biased and seemed to be smaller when using the scanner pipeline. There were systematic differences between devices, which was mainly driven by landmarks less clearly defined. The factors

conclusionsAs the scanner showed precision similar to the digitizer, a scanner should be used if the advantages of obtaining detailed 3D models of a specimen are desired. To obtain high precision, a pre-study should be conducted to identify difficult landmarks. Due to the observed bias, data from different devices and/or operators should not be combined when the expected biological variation is small, without testing the landmarks for repeatability across platforms and operators. For any study necessitating the combination of landmark measurements from different operators, the scanner pipeline will be better suited. The small scanning-related error indicates that by following the same scanning protocol, different operators can be involved in the scanning process without introducing significant error.

Indexed as

Generalized Procrustes analysisGeometric morphometricsHalichoerus grypusMeasurement errorMicroscribe digitizerProcrustes ANOVAShape variationStructured light scannerSystematic error

Identifiers

PMID34484981
PMCPMC8381885
OpenAlexW3194951410

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.