ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2021
Altered hemodynamics by 4D flow cardiovascular magnetic resonance predict exercise intolerance in repaired coarctation of the aorta: an in vitro study.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Three hours of targeted limb passive heating increases conduit artery shear rates and lowers vascular stiffness.Physiological reports · 2026Article
- Association of intraluminal thrombus in thoracoabdominal aortic aneurysms with a blood stasis model.Frontiers in cardiovascular medicine · 2026Article
- Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations.Journal of biomechanical engineering · 2025Article
- Greater than the sum of its parts: multimodality imaging in adults with congenital heart disease.Cardiovascular diagnosis and therapy · 2024Review
- Assessment of descending aortic blood flow velocities with continuous wave Doppler echocardiography among healthy Children in South East Nigeria.Malawi medical journal : the journal of Medical Association of Malawi · 2024Article
- Novel Techniques in Imaging Congenital Heart Disease: JACC Scientific Statement.Journal of the American College of Cardiology · 2024Review
- Aortic arch shape after arch repair predicts exercise capacity: a multicentre analysis.European heart journal open · 2024Article
- Non-Invasive Imaging Assessment in Patients with Aortic Coarctation: A Contemporary Review.Journal of clinical medicine · 2023Review
- Location matters: Offset in tissue-engineered vascular graft implantation location affects wall shear stress in porcine models.JTCVS open · 2022Article
- A Hemodynamic Analysis of the Thrombosis Within Occluded Coronary Arterial Fistulas With Terminal Aneurysms Using a Blood Stasis Model.Frontiers in physiology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundCoarctation of the aorta (CoA) is associated with decreased exercise capacity despite successful repair. Altered flow patterns have been identified due to abnormal aortic arch geometry. Our previous work demonstrated aorta size mismatch to be associated with exercise intolerance in this population. In this study, we studied aortic flow patterns during simulations of exercise in repaired CoA using 4D flow cardiovascular magnetic resonance (CMR) using aortic replicas connected to an in vitro flow pump and correlated findings with exercise stress test results to identify biomarkers of exercise intolerance.
methodsPatients with CoA repair were retrospectively analyzed after CMR and exercise stress test. Each aorta was manually segmented and 3D printed. Pressure gradient measurements from ascending aorta (AAo) to descending aorta (DAo) and 4D flow CMR were performed during simulations of rest and exercise using a mock circulatory flow loop. Changes in wall shear stress (WSS) and secondary flow formation (vorticity and helicity) from rest to exercise were quantified, as well as estimated DAo Reynolds number. Parameters were correlated with percent predicted peak oxygen consumption (VO2
resultsFifteen patients were identified (VO2
conclusionsThere are important associations between secondary flow characteristics and exercise capacity in repaired CoA that are not captured by traditional pressure gradient, likely due to increased turbulence and inefficient flow. These 4D flow CMR parameters are a target of investigation to identify optimal aortic arch geometry and improve long term clinical outcomes after CoA repair.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.