ArticleMedical physics2021
Tetrahedron beam imaging with a multi-pixel thermionic emission X-ray source and a photon-counting detector: A benchtop experimental study.
Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Simulation study of a novel small animal FLASH irradiator (SAFI) with integrated inverse-geometry CT based on circularly distributed kV X-ray sources.Scientific reports · 2023Article
- Design and optimization of thin-film tungsten (W)-diamond target for multi-pixel X-ray sources.Medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
purposeA tetrahedron beam (TB) X-ray system with a linear X-ray source array and a linear detector array positioned orthogonal to each other may overcome the X-ray scattering problem of traditional cone-beam X-ray systems. We developed a TB imaging benchtop system using a linear array X-ray source to demonstrate the principle and benefits of TB imaging.
methodsA multi-pixel thermionic emission X-ray (MPTEX) source with 48 focal spots in 4-mm spacing was developed in-house. The X-ray beams are collimated to a stack of fan beams that are converged to a 6-mm wide multi-row photon-counting detector (PCD). The data collected with a sequential scan of the sources at a fixed view angle were synthesized to a 2D radiography image by a shift-and-add algorithm. The data collected with a full rotation of the system were reconstructed into 3D TB CT (TBCT) images using an Feldkamp, Davis, and Kress (FDK)-based computed tomography (CT) algorithm modified for the TB geometry.
resultsWith an 18.8-cm long source array and a 35-cm long detector array, the TB benchtop system provides a 25-cm cross-sectional and 8-cm axial field of view (FOV). The scatter-to-primary ratio (SPR) was approximately 17% for TB, as compared with 120% for cone beam geometry. The TBCT system enables reconstructions in two-dimensional radiography and three-dimensional volumetric CT. The TBCT images were free of "cupping" artifacts and have similar image quality as diagnostic helical CT.
conclusionsA TB imaging benchtop imaging system was successfully developed with MPTEX source and PCD. Phantom and animal cadaver imaging demonstrated that the TB system can produce satisfactory radiographic X-ray images and 3D CT images with image quality comparable to diagnostic helical CTs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.