ArticleMedical physics2021

Dose calculation accuracy in particle therapy: Comparing carbon ions with protons.

Sirinya Ruangchan, Hugo Palmans, Barbara Knäusl, Dietmar Georg, Monika Clausen

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Helium pencil beam commissioning and beam modeling.Physics and imaging in radiation oncology · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Sirinya RuangchanDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Hugo PalmansDivision of Medical Physics, MedAustron Ion Therapy Center, Wiener Neustadt, Austria.
Barbara KnäuslDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Dietmar GeorgDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Monika ClausenDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Medical University of Vienna · ATMedAustron · ATNational Physical Laboratory · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis work presents the validation of an analytical pencil beam dose calculation algorithm in a commercial treatment planning system (TPS) for carbon ions by measurements of dose distributions in heterogeneous phantom geometries. Additionally, a comparison study of carbon ions versus protons is performed considering current best solutions in commercial TPS.

methodsAll treatment plans were optimized and calculated using the RayStation TPS (RaySearch, Sweden). The dose distributions calculated with the TPS were compared with measurements using a 24-pinpoint ionization chamber array (T31015, PTW, Germany). Tissue-like inhomogeneities (bone, lung, and soft tissue) were embedded in water, while a target volume of 4 x 4 x 4 cm

resultsInside the target volume, the mean dose difference between calculations and measurements, averaged over all test cases, was 1.6% for carbon ions. This compares well to the final agreement of 1.5% obtained in water at the commissioning stage of the TPS for carbon ions and is also within the clinically acceptable interval of 3%. The mean dose difference and maximal dose difference obtained outside the target area were 1.8% and 13.4%, respectively. The agreement of dose distributions for carbon ions in the target volumes was comparable or better to that between Monte Carlo (MC) dose calculations and measurements for protons. Percentage dose differences of more than 10% were present outside the target area behind bone-lung structures, where the carbon ion calculations systematically over predicted the dose. MC dose calculations for protons were superior to carbon ion beams outside the target volumes.

conclusionThe pencil beam dose calculations for carbon ions in RayStation were found to be in good agreement with dosimetric measurements in heterogeneous geometries for points of interest located within the target. Large local discrepancies behind the target may contribute to incorrect dose predictions for organs at risk.

Indexed as

ProtonsProton TherapyAlgorithmsCarbonMonte Carlo MethodPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedCarbonProtonscarbon ionsdose calculation algorithmsheterogeneous phantomprotons

Identifiers

PMID34482555
PMCPMC9291072
OpenAlexW3196631857

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.