Evidence map›Paper›PMID 34480801›Full record

ArticleMedical physics2021

Catheter position prediction using deep-learning-based multi-atlas registration for high-dose rate prostate brachytherapy.

Yang Lei, Tonghe Wang, Yabo Fu, Justin Roper, Ashesh B Jani, Tian Liu, Pretesh Patel, Xiaofeng Yang

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Systematic review of artificial intelligence in brachytherapy.Journal of contemporary brachytherapy · 2026
    Review
  3. Article
  4. A review of artificial intelligence in brachytherapy.Journal of applied clinical medical physics · 2025
    Review
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Yang LeiDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Tonghe WangDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Yabo FuDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Justin RoperDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Ashesh B JaniDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Tian LiuDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Pretesh PatelDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Xiaofeng YangDepartment of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Emory University · USPiedmont Cancer Institute · US

Funding

Multiparametric MRI-guided Prostate HDR Brachytherapy with Focal Tumor BoostR01CA215718 · NCI · EMORY UNIVERSITY · PI YANG, XIAOFENG · 2018 to 2022
$1.8M
NCI NIH HHS R01 CA215718NCI NIH HHS R01CA215718
6 · The paper itself

Abstract

purposeHigh-dose-rate (HDR) prostate brachytherapy involves treatment catheter placement, which is currently empirical and physician dependent. The lack of proper catheter placement guidance during the procedure has left the physicians to rely on a heuristic thinking-while-doing technique, which may cause large catheter placement variation and increased plan quality uncertainty. Therefore, the achievable dose distribution could not be quantified prior to the catheter placement. To overcome this challenge, we proposed a learning-based method to provide HDR catheter placement guidance for prostate cancer patients undergoing HDR brachytherapy.

methodsThe proposed framework consists of deformable registration via registration network (Reg-Net), multi-atlas ranking, and catheter regression. To model the global spatial relationship among multiple organs, binary masks of the prostate and organs-at-risk are transformed into distance maps, which describe the distance of each local voxel to the organ surfaces. For a new patient, the generated distance map is used as fixed image. Reg-Net is utilized to deformably register the distance maps from multi-atlas set to match this patient's distance map and then bring catheter maps from multi-atlas to this patient via spatial transformation. Several criteria, namely prostate volume similarity, multi-organ semantic image similarity, and catheter position criteria (far from the urethra and within the partial prostate), are used for multi-atlas ranking. The top-ranked atlas' deformed catheter positions are selected as the predicted catheter positions for this patient. Finally, catheter regression is used to refine the final catheter positions. A retrospective study on 90 patients with a fivefold cross-validation scheme was used to evaluate the proposed method's feasibility. In order to investigate the impact of plan quality from the predicted catheter pattern, we optimized the source dwell position and time for both the clinical catheter pattern and predicted catheter pattern with the same optimization settings. Comparisons of clinically relevant dose volume histogram (DVH) metrics were completed.

resultsFor all patients, on average, both the clinical plan dose and predicted plan dose meet the common dose constraints when prostate dose coverage is kept at V100 = 95%. The plans from the predicted catheter pattern have slightly higher hotspot in terms of V150 by 5.0% and V200 by 2.9% on average. For bladder V75, rectum V75, and urethra V125, the average difference is close to zero, and the range of most patients is within ±1 cc.

conclusionWe developed a new catheter placement prediction method for HDR prostate brachytherapy based on a deep-learning-based multi-atlas registration algorithm. It has great clinical potential since it can provide catheter location estimation prior to catheter placement, which could reduce the dependence on physicians' experience in catheter implantation and improve the quality of prostate HDR treatment plans. This approach merits further clinical evaluation and validation as a method of quality control for HDR prostate brachytherapy.

Indexed as

BrachytherapyDeep LearningProstatic NeoplasmsCathetersHumansMaleProstateRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective Studiescatheterdeep learningHDRprostate

Identifiers

PMID34480801
PMCPMC8595586
OpenAlexW3197087278

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.