Evidence map›Paper›PMID 34476528›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2021

Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent.

Hongya Dai, Dingqiang Yang, Lu Chen, Yibing Zhou, Xiaojing Wen, Jianguo Sun, Guanghui Li

Open access · hybridAbstract readClinical Trial Protocol
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Hongya DaiDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Dingqiang YangDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Lu ChenDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Yibing ZhouDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Xiaojing WenDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Jianguo SunDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China.
Guanghui LiDepartment of Oncology, Xinqiao Hospital, Army Medical University, Chongqing, China. liguanghui_2000@aliyun.com.
Xinqiao Hospital · CNArmy Medical University · CN

Funding

Chongqing Science and Health Joint Project 2021MSXM154
6 · The paper itself

Abstract

purposeThe accuracy of target delineation for node-positive thoracic tumors is dependent on both four-dimensional computed tomography (4D-CT) and contrast-enhanced three-dimensional (3D)-CT images; these scans enable the motion visualization of tumors and delineate the nodal areas. Combining the two techniques would be more effective; however, currently, there is no standard protocol for the contrast media injection parameters for contrast-enhanced 4D-CT (CE-4D-CT) scans because of its long scan durations and complexity. Thus, we aimed to perform quantitative and qualitative assessments of the image quality of single contrast-enhanced 4D-CT scans to simplify this process and improve the accuracy of target delineation in order to replace the standard clinical modality involved in administering radiotherapy for thoracic tumors.

methodsNinety consecutive patients with thoracic tumors were randomly and parallelly assigned to one of nine subgroups subjected to CE-4D-CT scans with the administration of contrast agent volume equal to the patient's weight but different flow rate and scan delay time (protocol A1: flow rate of 2.0 ml/s, delay time of 15 s; A2: 2.0 ml/s, 20 s; A3: 2.0 ml/s, 25 s; B1: 2.5 ml/s, 15 s; B2: 2.5 ml/s, 20 s; B3: 2.5 ml/s, 25 s; C1: 3.0 ml/s, 15 s; C2: 3.0 ml/s, 20 s; C3: 3.0 ml/s, 25 s). The Hounsfield unit (HU) values of the thoracic aorta, pulmonary artery stem, pulmonary veins, carotid artery, and jugular vein were acquired for each protocol. Both quantitative and qualitative image analysis and delineation acceptability were assessed.

resultsThe results revealed significant differences among the nine protocols. Enhancement of the vascular structures in mediastinal and perihilar regions was more effective with protocol A1 or A2; however, when interested in the region of superior mediastinum and supraclavicular fossa, protocol C2 or C3 is recommended.

conclusionQualitatively acceptable enhancement on contrast-enhanced 4D-CT images of thoracic tumors can be obtained by varying the flow rate and delay time when minimal contrast agent is used.

Indexed as

Contrast MediaThoracic NeoplasmsCarotid ArteriesFour-Dimensional Computed TomographyHumansRandomized Controlled Trials as TopicThoraxContrast Media4D computed tomographyContrast agentCT image enhancementRadiotherapyThoracic tumors

Identifiers

PMID34476528
PMCPMC8547213
OpenAlexW3198076828

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked