Evidence map›Paper›PMID 34475281›Full record

ArticleJournal of synchrotron radiation2021

New high-throughput endstation to accelerate the experimental optimization pipeline for synchrotron X-ray footprinting.

Rohit Jain, Donald Abel, Maksim Rakitin, Michael Sullivan, David T Lodowski, Mark R Chance, Erik R Farquhar

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rohit JainCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.ORCID 0000-0002-0780-1869
Donald AbelCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.
Maksim RakitinNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.ORCID 0000-0003-3685-852X
Michael SullivanCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.
David T LodowskiCenter for Proteomics and Bioinformatics, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.ORCID 0000-0002-8783-4328
Mark R ChanceCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.ORCID 0000-0002-2991-6405
Erik R FarquharCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.ORCID 0000-0002-6419-038X

Funding

Case Center for Synchrotron BiosciencesP30EB009998 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CHANCE, MARK R · 2009 to 2018
$8.4M
Air Force Research Laboratory FA8650-18-2-5402National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering P30-EB-009998National Science Foundation DBI-1228549NIBIB NIH HHS P30 EB009998U.S. Department of Energy, Office of Science DE-SC0012704
6 · The paper itself

Abstract

Synchrotron X-ray footprinting (XF) is a growing structural biology technique that leverages radiation-induced chemical modifications via X-ray radiolysis of water to produce hydroxyl radicals that probe changes in macromolecular structure and dynamics in solution states of interest. The X-ray Footprinting of Biological Materials (XFP) beamline at the National Synchrotron Light Source II provides the structural biology community with access to instrumentation and expert support in the XF method, and is also a platform for development of new technological capabilities in this field. The design and implementation of a new high-throughput endstation device based around use of a 96-well PCR plate form factor and supporting diagnostic instrumentation for synchrotron XF is described. This development enables a pipeline for rapid comprehensive screening of the influence of sample chemistry on hydroxyl radical dose using a convenient fluorescent assay, illustrated here with a study of 26 organic compounds. The new high-throughput endstation device and sample evaluation pipeline now available at the XFP beamline provide the worldwide structural biology community with a robust resource for carrying out well optimized synchrotron XF studies of challenging biological systems with complex sample compositions.

Indexed as

Equipment DesignHydroxyl RadicalProtein ConformationProtein FootprintingProteinsSynchrotronsWaterX-RaysHydroxyl RadicalProteinsWaterBlueskyhigh throughputhydroxyl radical footprintingmacromolecular dynamicsnucleic acidsprotein structureX-ray radiolysis

Identifiers

PMID34475281
PMCPMC8415340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.