ArticleUltrasonics2022
Acoustic-resolution photoacoustic microscope based on compact and low-cost delta configuration actuator.
Article in Ultrasonics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Robot-assisted minimally invasive photoacoustic imaging for monitoring liver ablation using diffusing fiber illumination.Journal of biomedical optics · 2026Article
- An Ultra-Low-Cost Optoacoustic Method for Imaging Specific Biological Structures.Diagnostics (Basel, Switzerland) · 2026Article
- Spectroscopic photoacoustic denoising framework using hybrid analytical and data-free learning method.Photoacoustics · 2025Article
- Miniaturized side-firing intracardiac photoacoustic imaging catheter for monitoring radiofrequency ablation.Scientific reports · 2025Article
- Needle hydrophone-based photoacoustic microscopy with experimentally measured impulse response for improved depth of focus.Biomedical optics express · 2025Article
- Cardiac-gated spectroscopic photoacoustic imaging for ablation-induced necrotic lesion visualization.Journal of biophotonics · 2024Article
- Enhancing boundary detection of radiofrequency ablation lesions through photoacoustic mapping.Scientific reports · 2024Article
- Laparoscopic Photoacoustic Imaging System Based on Side-Illumination Diffusing Fibers.IEEE transactions on bio-medical engineering · 2023Article
- Intraoperative laparoscopic photoacoustic image guidance system in the da Vinci surgical system.Biomedical optics express · 2023Article
- Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array.IEEE transactions on bio-medical engineering · 2023Article
- Fast iterative reconstruction for photoacoustic tomography using learned physical model: Theoretical validation.Photoacoustics · 2023Article
- Concentric-ring arrays for forward-viewing ultrasound imaging.Journal of medical imaging (Bellingham, Wash.) · 2022Article
- Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022Review
- Absolute Quantitative Photoacoustic Imaging for Contrast Agents Concentration Estimation Using a Spectral Decomposition Approach.Molecular imagingArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The state-of-the-art configurations for acoustic-resolution photoacoustic (PA) microscope (AR-PAM) are large in size and expensive, hindering their democratization. While previous research on AR-PAMs introduced a low-cost light source to reduce the cost, few studies have investigated the possibility of optimizing the sensor actuation, particularly for the AR-PAM. Additionally, there is an unmet need to evaluate the image quality deterioration associated with the actuation inaccuracy. A low-cost actuation device is introduced to reduce the system size and cost of the AR-PAM while maintaining the image quality by implementing the advanced beamformers. This work proposes an AR-RAM incorporating the delta configuration actuator adaptable from a low-cost off-the-shelf 3D printer as the sensor actuation device. The image degradation due to the data acquisition positioning inaccuracy is evaluated in the simulation. We further assess the mitigation of potential actuation precision uncertainty through advanced 3D synthetic aperture focusing algorithms represented by the Delay-and-Sum (DAS) with Coherence Factor (DAS+CF) and Delay-Multiply-and-Sum (DMAS) algorithms. The simulation study demonstrated the tolerance of image quality on actuation inaccuracy and the effect of compensating the actuator motion precision error through advanced reconstruction algorithms. With those algorithms, the image quality degradation was suppressed to within 25% with the presence of 0.2 mm motion inaccuracy. The experimental evaluation using phantoms and an ex-vivo sample presented the applicability of low-cost delta configuration actuators for AR-PAMs. The measured full width at half maximum of the 0.2 mm diameter pencil-lead phantom were 0.45 ± 0.06 mm, 0.31 ± 0.04 mm, and 0.35 ± 0.07 mm, by applying the DAS, DAS+CF, and DMAS algorithms, respectively. AR-PAMs with a compact and low-cost delta configuration provide high-quality PA imaging with better accessibility for biomedical applications. The research evaluated the image degradation contributed by the actuation inaccuracy and suggested that the advanced beamformers are capable of suppressing the actuation inaccuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.