Evidence map›Paper›PMID 34474357›Full record

ArticleUltrasonics2022

Acoustic-resolution photoacoustic microscope based on compact and low-cost delta configuration actuator.

Shang Gao, Ryosuke Tsumura, Doua P Vang, Keion Bisland, Keshuai Xu, Yasuyuki Tsunoi, Haichong K Zhang

Abstract read
In one paragraph

Article in Ultrasonics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array.IEEE transactions on bio-medical engineering · 2023
    Article
  11. Article
  12. Concentric-ring arrays for forward-viewing ultrasound imaging.Journal of medical imaging (Bellingham, Wash.) · 2022
    Article
  13. Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shang GaoWorcester Polytechnic Institute, Department of Robotics Engineering, 100 Institute Rd, Worcester 01609, United States.
Ryosuke TsumuraWorcester Polytechnic Institute, Department of Robotics Engineering, 100 Institute Rd, Worcester 01609, United States; Worcester Polytechnic Institute, Department of Biomedical Engineering, 100 Institute Rd, Worcester 01609, United States.
Doua P VangWorcester Polytechnic Institute, Department of Electrical and Computer Engineering, 100 Institute Rd, Worcester 01609, United States.
Keion BislandWorcester Polytechnic Institute, Department of Robotics Engineering, 100 Institute Rd, Worcester 01609, United States.
Keshuai XuJohns Hopkins University, Department of Computer Science, Baltimore 21218, United States.
Yasuyuki TsunoiNational Defense Medical College Research Institute, Division of Bioinformation and Therapeutic Systems, 3-2 Namiki, Tokorozawa 359-8513, Japan.
Haichong K ZhangWorcester Polytechnic Institute, Department of Robotics Engineering, 100 Institute Rd, Worcester 01609, United States; Worcester Polytechnic Institute, Department of Biomedical Engineering, 100 Institute Rd, Worcester 01609, United States; Worcester Polytechnic Institute, Department of Computer Science, 100 Institute Rd, Worcester 01609, United States. Electronic address: hzhang10@wpi.edu.

Funding

Training/Dissemination-Resource for Molecular Imaging Agents in Precision MedicineP41EB024495 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI Lilja Solnes · 2017 to 2026
$11.8M
PSMA-based Cancer Imaging AgentsR01CA134675 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI POMPER, MARTIN G · 2009 to 2025
$6.2M
Robotic Lung Ultrasound for Triage of COVID-19 Patients in a Resource-Limited EnvironmentDP5OD028162 · OD · WORCESTER POLYTECHNIC INSTITUTE · PI ZHANG, HAICHONG · 2019 to 2023
$2.3M
NCI NIH HHS R01 CA134675NIBIB NIH HHS P41 EB024495NIH HHS DP5 OD028162
6 · The paper itself

Abstract

The state-of-the-art configurations for acoustic-resolution photoacoustic (PA) microscope (AR-PAM) are large in size and expensive, hindering their democratization. While previous research on AR-PAMs introduced a low-cost light source to reduce the cost, few studies have investigated the possibility of optimizing the sensor actuation, particularly for the AR-PAM. Additionally, there is an unmet need to evaluate the image quality deterioration associated with the actuation inaccuracy. A low-cost actuation device is introduced to reduce the system size and cost of the AR-PAM while maintaining the image quality by implementing the advanced beamformers. This work proposes an AR-RAM incorporating the delta configuration actuator adaptable from a low-cost off-the-shelf 3D printer as the sensor actuation device. The image degradation due to the data acquisition positioning inaccuracy is evaluated in the simulation. We further assess the mitigation of potential actuation precision uncertainty through advanced 3D synthetic aperture focusing algorithms represented by the Delay-and-Sum (DAS) with Coherence Factor (DAS+CF) and Delay-Multiply-and-Sum (DMAS) algorithms. The simulation study demonstrated the tolerance of image quality on actuation inaccuracy and the effect of compensating the actuator motion precision error through advanced reconstruction algorithms. With those algorithms, the image quality degradation was suppressed to within 25% with the presence of 0.2 mm motion inaccuracy. The experimental evaluation using phantoms and an ex-vivo sample presented the applicability of low-cost delta configuration actuators for AR-PAMs. The measured full width at half maximum of the 0.2 mm diameter pencil-lead phantom were 0.45 ± 0.06 mm, 0.31 ± 0.04 mm, and 0.35 ± 0.07 mm, by applying the DAS, DAS+CF, and DMAS algorithms, respectively. AR-PAMs with a compact and low-cost delta configuration provide high-quality PA imaging with better accessibility for biomedical applications. The research evaluated the image degradation contributed by the actuation inaccuracy and suggested that the advanced beamformers are capable of suppressing the actuation inaccuracy.

Indexed as

Acoustic-resolution photoacoustic microscopyBeamformingDelta configuration actuatorPhotoacoustic imagingRobotics

Identifiers

PMID34474357
PMCPMC8530928

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.