Evidence map›Paper›PMID 34470296›Full record

ArticleThe Journal of the Acoustical Society of America2021

Temporal integration of monaural and dichotic frequency modulation.

Katherine N Palandrani, Eric C Hoover, Trevor Stavropoulos, Aaron R Seitz, Sittiprapa Isarangura, Frederick J Gallun, David A Eddins

Abstract read
In one paragraph

Article in The Journal of the Acoustical Society of America, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Effect of Selective Carboplatin-Induced Inner Hair Cell Loss on Temporal Integration in Chinchillas.Journal of the Association for Research in Otolaryngology : JARO · 2022
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Katherine N PalandraniDepartment of Communication Sciences and Disorders, University of Maryland, College Park, Maryland 20742, USA.
Eric C HooverDepartment of Communication Sciences and Disorders, University of Maryland, College Park, Maryland 20742, USA.
Trevor StavropoulosBrain Game Center, University of California Riverside, Riverside, California 92521, USA.
Aaron R SeitzDepartment of Psychology, University of California Riverside, Riverside, California 92521, USA.
Sittiprapa IsaranguraDepartment of Communication Sciences and Disorders, Mahidol University, Phaya Thai, Bangkok 10400, Thailand.
Frederick J GallunOregon Hearing Research Center, Oregon Health and Science University, Portland, Oregon 97239, USA.
David A EddinsDepartment of Communication Sciences and Disorders, University of South Florida, Tampa, Florida 33620, USA.

Funding

Structure and Function Services CoreP01AG009524 · NIA · UNIVERSITY OF SOUTH FLORIDA · PI FRISINA, ROBERT D · 1992 to 2021
$23.2M
Efficient diagnostic tools to evaluate central auditory dysfunctionR01DC015051 · NIDCD · OREGON HEALTH & SCIENCE UNIVERSITY · PI EDDINS, DAVID A., GALLUN, FREDERICK J. · 2016 to 2020
$2.3M
NIA NIH HHS P01 AG009524NIDCD NIH HHS R01 DC015051
6 · The paper itself

Abstract

Frequency modulation (FM) detection at low modulation frequencies is commonly used as an index of temporal fine-structure processing. The present study evaluated the rate of improvement in monaural and dichotic FM across a range of test parameters. In experiment I, dichotic and monaural FM detection was measured as a function of duration and modulator starting phase. Dichotic FM thresholds were lower than monaural FM thresholds and the modulator starting phase had no effect on detection. Experiment II measured monaural FM detection for signals that differed in modulation rate and duration such that the improvement with duration in seconds (carrier) or cycles (modulator) was compared. Monaural FM detection improved monotonically with the number of modulation cycles, suggesting that the modulator is extracted prior to detection. Experiment III measured dichotic FM detection for shorter signal durations to test the hypothesis that dichotic FM relies primarily on the signal onset. The rate of improvement decreased as duration increased, which is consistent with the use of primarily onset cues for the detection of dichotic FM. These results establish that improvement with duration occurs as a function of the modulation cycles at a rate consistent with the independent-samples model for monaural FM, but later cycles contribute less to detection in dichotic FM.

Indexed as

CuesTime PerceptionAuditory ThresholdTime Factors

Identifiers

PMID34470296
PMCPMC8337085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.