Evidence map›Paper›PMID 34470181›Full record

ArticleJournal of imaging2018

Magnetic Resonance Conditional Microinjector.

Adam Wineland, Yue Chen, Brian Boland, Kevin Chan, Zion Tse

Abstract read
In one paragraph

Article in Journal of imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Open Source MR-Safe Pneumatic Radial Inflow Motor and Encoder (PRIME): Design and Manufacturing Guidelines.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2023
    Article
  2. MR-Conditional Actuations: A Review.Annals of biomedical engineering · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adam WinelandSchool of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA.
Yue ChenDepartment of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
Brian BolandSchool of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA.ORCID 0000-0001-9903-2448
Kevin ChanNeuroimaging and Visual Science Laboratory, Departments of Ophthalmology and Radiology, NYU School of Medicine, New York University, New York, NY 10016, USA.ORCID 0000-0003-4012-7084
Zion TseSchool of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA.ORCID 0000-0001-9741-1137

Funding

Center for Clinical and Translational Research Unit Seed GrantNIH HHS 1ZIDNIH HHS BC011242NIH HHS CL040015University of Georgia UGA-AU Inter-Institutional Seed FundingU.S. Public Health Service UL1TR000454
6 · The paper itself

Abstract

Glaucoma, one of the leading causes of blindness, has been linked to increases in intraocular pressure. In order to observe and study this effect, proposed is a specialized microinjector and driver that can be used to inject small amounts of liquid into a target volume. Magnetic resonance imaging (MRI) guided remotely activated devices require specialized equipment that is compatible with the MR environment. This paper presents an MR Conditional microinjector system with a pressure sensor for investigating the effects of intraocular pressure (IOP) in near-real-time. The system uses pressurized air and a linear actuation device to push a syringe in a controlled, stepwise manner. The feasibility and utility of the proposed investigative medical research tool were tested and validated by measuring the pressure inside an intact animal donor eyeball while precise, small volumes of water were injected into the specimen. Observable increases in the volume of the specimen at measured, specific target pressure increases show that the system is technically feasible for studying IOP effects, while the changes in shape were depicted in MRI scan images themselves. In addition, it was verified that the presence and operation of the system did not interfere with the MRI machine, confirming its conditional compatibility with the 3T MRI.

Indexed as

actuationblindnesseyeglaucomaimage guidedintraocular pressuremagnetic resonancemicroinjectorMRIpneumatic

Identifiers

PMID34470181
PMCPMC8320858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.